Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
PBA100FBlock diagramPBA/PBWAC IN 85 - 264VFUSE250V3.15ANOISEFILTERRECTIFIERINRUSHCURRENTLIMITFGCURRENTSENSINGOPTIONRCBOOSTERINDUCTORCURRENTSENSINGRECTIFIERANDFILTERCONTROLCONTROLEXTERNALSOURCEEINVERTERINVERTEROVER VOLTAGEPROTECTIONCONTROLTRANSFORMERRECTIFIERANDFILTERDC OUTExternal view¶External size of option T,J1,R,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details.CN3Connector for Remote ON/OFF (option)Voltage adjust(81)[3.19]+V+V-V-VFG( )AC(L)AC(N)(20)[0.79](11)[0.43]M4LEDTerminal coverCover (option)8.6[0.34]10[0.39](10)[0.39]CN4Connector for Remote sensing (option : only -3R3, -5)(13.5)147[0.53] [5.79]1 22-M3Mounting hole33.5[1.32]930.5[3.66] [0.02]APoint A(14)[0.55](23.5)[0.93]124±0.54[4.88][0.16]3-M3MountingholeName plate3.5[0.14]Connector typeCN3 Option (Mfr : J.S.T.)Pin No. Contents1 RC(+)2 RC( -)¶Tolerance :±1[±0.04]¶Weight : 440g max (with cover : 500g max)¶PCB Material/thickness : CEM3 / 1.6mm [0.06]¶Chassis material : Aluminum¶Dimensions in mm, [ ]= inches¶Mounting torque : 0.49N ? m(5kgf ? cm)max¶Mounting torque : M4:1.6N ? m(16.9kgf ? cm)max18[0.71]¶Please connect safety ground to FG terminal on the unit.PBA100F112.5±0.515[4.43][0.59]13±0.5[0.51]32[1.26]9.5[0.37]Barrier strip typeModel B2B-XH-AMating Connector (Terminal)XHP-2BXH-001T-P0.6( or SXH-001T-P0.6)? 61 ?PBA/PBW-13