title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
642/916

This page is the summary of page 642 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RAC-DC Power Supplies DIN Rail TypeKLEA/KLNA240FUL508Ordering informationKLO A 240 F -OO -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-06-472-DHigh voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series nameKLE : Euro Style I/O TerminalsKLN : Barrier Blocks StyleI/O Terminals2 Single output3 Output wattage4 Universal input5 Output voltage6 OptionC : with CoatingN2 : Screw mounting*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELKLEA/KLNA240F-24KLEA/KLNA240F-48MAX OUTPUT WATTAGE[W]240240DC OUTPUT24V 10A48V 5ASPECIFICATIONSMODEL KLEA/KLNA240F-24 KLEA/KLNA240F-48KLVOLTAGE[V]AC85 - 264 1f (Refer to“Derating”) *8CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 66)ACIN 115V 88typEFFICIENCY[%]INPUTACIN 230V 90typPOWER FACTORINRUSH CURRENT[A]ACIN 115V20typ (Io=100%)(at cold start Ta=25C)*1 ACIN 230V40typ (Io=100%)(at cold start Ta=25C)LEAKAGE CURRENT[mA]0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]2448CURRENT[A]105LINE REGULATION[mV]*296max192maxLOAD REGULATION[mV]*2150max300max0 to +70C 150max 150maxRIPPLE[mVp-p] *3-20 - 0C 240max 240max0 to +70C 180max 180maxRIPPLE NOISE[mVp-p] *3OUTPUT-20 - 0C 300max 300max0 to +70C 240max 480maxTEMPERATURE REGULATION[mV]-20 to +70C 290max 600maxDRIFT[mV]*496max192maxSTART-UP TIME[ms]500typ (ACIN 115V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 115V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]21.60 to 26.4043.20 to 52.80OUTPUT VOLTAGE SETTING[V]24.00 to 24.9648.00 to 49.92PROTECTIONOVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyCIRCUIT ANDOVERVOLTAGE PROTECTION[V]27.60 to 33.6054.00 to 67.20OTHERSDC_OK LAMPLED (Green)INPUT-OUTPUTAC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature)ISOLATIONINPUT-PEAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature)OUTPUT-PEAC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-20 to +70C, 20 - 90%RH (Non condensing), Type tested for -40C start-up (Refer to“Derating”)ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axis (Packing state)SAFETY ANDAGENCY APPROVALSUL60950-1, C-UL (CSA60950-1), EN62368-1, UL508, Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2(Class A) *5CASE SIZE*650X124X117mm (WXHXD) [1.97X4.88X4.61 inches]OTHERSWEIGHT750g maxCOOLING METHODConvection*1 The value is primary surge. The current of input surge to a built-in EMI/EMCFilter(0.2ms or less)is excluded.*2 Please contact us about dynamic load and input response.*3 This is the value that measured on measuring board with capacitor of 22mFand 0.1mF at 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent toKEISOKU-GIKEN: RM103).Please refer to the instruction manual 1.5.KL-4*4 Drift is the change in DC output for an eight hour period after a half-hourwarm-up at 25C, with the input voltage held constant at the rated input/output.*5 Please contact us about another class.*6 Case size contains neither the umbo.*7 Only as standard mounting orientation (A). Refer to“Assembling andInstallation Method”.If install other than standard mounting orientation (A), please fi x the power? 640 ?supply for withstand the vibration and impact.*8 Please contact us about DC input voltage.* To meet the specifi cations. Do not operate over-loaded condition.* A sound may occur from power supply at light or peak loading.