title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
656/916

This page is the summary of page 656 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Medical TypeAEA800FOrdering informationAE A 800 F -OO -O1 2 3 4 5 6AEA2MOPPAEA-4RPlease refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELAEA800F-24AEA800F-30AEA800F-36AEA800F-48MAX OUTPUT WATTAGE[W]816816817816DC OUTPUT (forced air)SPECIFICATIONSMODELAEA800F-24AEA800F-30AEA800F-36AEA800F-48VOLTAGE[V]AC85 - 264 1f (Output derating is required at AC85 - 170V. See“Derating”)CURRENT[A]FREQUENCY[Hz]50/60 (45 - 66)ACIN 100V 92.5typ (Io=25.5A) 92.5typ (Io=20.4A) 92.5typ (Io=17.0A) 92.5typ (Io=12.7A)EFFICIENCY[%]INPUTACIN 230V 95.0typ (Io=34.0A) 95.0typ (Io=27.2A) 95.5typ (Io=22.7A) 95.5typ (Io=17.0A)POWER FACTORACIN 100V 20/40typ (Io=25.5A) 20/40typ (Io=20.4A) 20/40typ (Io=17.0A) 20/40typ (Io=12.7A)INRUSH CURRENT[A] *2ACIN 230V 40/40typ (Io=34.0A) 40/40typ (Io=27.2A) 40/40typ (Io=22.7A) 40/40typ (Io=17.0A)LEAKAGE CURRENT[mA]0.3max (ACIN 240V 60Hz, Io=100%, According to IEC60601-1)VOLTAGE[V]24303648CURRENT[A]LINE REGULATION[mV]96max120max144max192maxLOAD REGULATION[mV]150max200max240max300max0 to +50C 120max 200max 200max 250maxRIPPLE[mVp-p] *3OUTPUT-20 to 0C 230max 300max 300max 400maxRIPPLE NOISE[mVp-p] *3TEMPERATURE REGULATION[mV]0 to +50C240max300max360max480maxDRIFT[mV]*496max120max144max192maxSTART-UP[ms]550typ (ACIN 100V/230V) 750typ (ACIN 85V-264V)HOLD-UP[ms]20typ (ACIN 230V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]21.6 to 26.427.0 to 33.032.4 to 39.643.2 to 52.8OUTPUT VOLTAGE SETTING[V]23.5 to 24.529.0 to 31.035.0 to 37.047.0 to 49.0OVERCURRENT PROTECTIONWorks over 101% of peak current and recovers automatically *5OVERVOLTAGE PROTECTION[V] 30 to 33.6 37.5 to 42.0 45 to 50.4 60 to 69.6PROTECTIONALARMOptional (Input voltage alarm : PR, Output voltage alarm : PG)CIRCUIT ANDREMOTE ON/OFFOptionalOTHERSAUX1Optional (12V1A forced air)AUX2Optional (5V1A forced air)INPUT-OUTPUT-PR-PG-RC-AUX *6AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MΩmin (At Room Temperature) 2MOPPISOLATIONOUTPUT-AUX1-PR-PG-RC-AUX2 *6AC100V 1minute, Cutoff current = 25mA, DC100V 10MΩmin (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-20 to +70C, 20 - 90%RH (Non condensing), 5,000m (16,500feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisUL62368-1, ANSI/AAMI ES 60601-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1, CAN/CSA-C22.2 No.60601-1)SAFETY AND AGENCY APPROVALSEN62368-1, EN60601-1 3rd, EN62477-1 (OVCIII), UL508 (Optional), Complies with IEC60601-1-2 4th Ed.NOISECONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR32-B, EN55011-B, EN55032-BREGULATIONSHARMONIC ATTENUATOR *7 Complies with IEC61000-3-2 (Class A)OTHERS*1 The listed options may affect the published standard specifi cations.Please contact us for detailed product specifi cation*2 The current of input surge to a built-in EMI/EMS Filter (0.2ms or less) is excluded.*3 Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKUGIKEN:RM104).Please refer to the instruction manual 1.8.*4 Drift is the change in DC output for an eight hours period after a half-hour warm-up at 25C? 654 ?Example recommended EMI/EMC filterNAC-30-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* Use of an EMI/EMC filter is recommendedwhen a power supply is connected with severaldevices so that additional filtering is necessary.* Make sure that your final application will meetthe required EMC standard by measuring theEMI level of the power supply used togetherwith an EMI/EMC filter.*5 When the overcurrent protection continues,the output may be shut down.*6 Applicable when AUX and remote control (optional) is added.*7 Please contact us about another class.* Sound noise may be generated by power supply in case of pulse load.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1C : with CoatingN : with coverT : Vertical terminal blockJ : Connector typeR3 : with Subfeatures(5V1A AUX,12V1A AUXRemote ON/OFF, Alarm)I4: with MODBUS interface and Subfeatures(5V1A AUX,12V1A AUXRemote ON/OFF, Alarm)T5 : UL508 (Except 30V)P5 : shutdown type overcurrentprotectionFor option details, refer to instructionmanual 6.1.