title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
656/1330

This page is the summary of page 656 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

DC-DC Converters PCB Mount TypeInstruction Manual?SU/SUC10SUS10053R3SUS10123R3SUS10243R3SUS10483R3SUS100505SUS101205SUS102405SUS104805SUS100512SUS101212SUS102412SUS104812SUS100515SUS101215SUS102415SUS104815SUW100512SUW101212SUW102412SUW104812SUW100515SUW101215SUW102415SUW104815SUCS10053R3SUCS10123R3SUCS10243R3SUCS10483R3SUCS100505SUCS101205SUCS102405SUCS104805SUCS100512SUCS101212SUCS102412SUCS104812SUCS100515SUCS101215SUCS102415SUCS104815SUCW100512SUCW101212SUCW102412SUCW104812SUCW100515SUCW101215SUCW102415SUCW104815?SUT3SUTS3053R3SUTS3123R3SUTS3243R3SUTS3483R3SUTS30505SUTS31205SUTS32405SUTS34805SUTS30512SUTS31212SUTS32412SUTS34812SUTS30515SUTS31215SUTS32415SUTS34815SUTW30512SUTW31212SUTW32412SUTW34812SUTW30515SUTW31215SUTW32415SUTW34815?SUT6SUTS6053R3SUTS6123R3SUTS6243R3SUTS6483R3SUTS60505SUTS61205SUTS62405SUTS64805SUTS60512SUTS61212SUTS62412SUTS64812SUTS60515SUTS61215SUTS62415SUTS64815SUTW60512SUTW61212SUTW62412SUTW64812SUTW60515SUTW61215SUTW62415SUTW64815?SUT10SUTS10053R3SUTS10123R3SUTS10243R3SUTS10483R3SUTS100505SUTS101205SUTS102405SUTS104805SUTS100512SUTS101212SUTS102412SUTS104812SUTS100515SUTS101215SUTS102415SUTS104815SUTW100512SUTW101212SUTW102412SUTW104812SUTW100515SUTW101215SUTW102415SUTW1048157 TemperatureMeasuring Point7.1 SU/SUC1R51 SU1R5!In the case of forced air cooling (1m/s), please have sufficientventilation to keep the temperature of point A in Fig.7.1 at 105Cor below.Please also make sure that the ambient temperature does not exceed85C.Point AFig.7.1 Temperature Measuring Point in the case of Forced Air Cooling2 SUC1R5!In the case of forced air cooling (1m/s), please have sufficientventilation to keep the temperature of point B in Fig.7.2 at 95C orbelow.Please also make sure that the ambient temperature does not exceed85C.Point B (Center of the Case)Fig.7.2 Temperature Measuring Point in the case of Forced Air Cooling(Upper Surface of the Case)7.2 SU/SUC31 SU3!In the case of forced air cooling (1m/s), please have sufficientventilation to keep the temperature of point A in Fig.7.3 at 115C orbelow and that of Point B at 120C or below.Please also make sure that the ambient temperature does not exceed85C.Point APoint BFig.7.3 Temperature Measuring Points in the case of Forced Air CoolingSU . SUC/SUT-56