COSEL Power Supply, Noise Filter 2025 Product Catalog

DC-DC Converters PCB Mount TypeInstruction Manual2 SUC3!In the case of forced air cooling (1m/s), please have sufficientventilation to keep the temperature of point C in Fig.7.4 at 100Cor below.Please also make sure that the ambient temperature does not exceed85C.Point C (Center of the Case)7.4 SU/SUC101 SU10!In the case of forced air cooling (1m/s), please have sufficientventilation to keep the temperature of point A in Fig.7.7 at 105Cor below.Please also make sure that the ambient temperature does not exceed85C.Fig.7.4 Temperature Measuring Point in the case of Forced Air Cooling(Upper Surface of the Case)7.3 SU/SUC61 SU6!In the case of forced air cooling (1m/s), please have sufficientventilation to keep the temperature of point A in Fig.7.5 at 95C orbelow and that of Point B at 115C or below.Please also make sure that the ambient temperature does not exceed85C.Point AFig.7.7 Temperature Measuring Point in the case of Forced Air Cooling2 SUC10!In the case of forced air cooling (1m/s), please have sufficientventilation to keep the temperature of point B in Fig.7.8 at 95C orbelow.Please also make sure that the ambient temperature does not exceed85C.Point B (Center of the Case)Point BPoint AFig.7.5 Temperature Measuring Points in the case of Forced Air Cooling2 SUC6!In the case of forced air cooling (1m/s), please have sufficientventilation to keep the temperature of point C in Fig.7.6 at 95C orbelow.Please also make sure that the ambient temperature does not exceed85C.Point C (Center of the Case)Fig.7.8 Temperature Measuring Point in the case of Forced Air Cooling(Upper Surface of the Case)7.5 SUT3!In the case of forced air cooling (1m/s), please have sufficientventilation to keep the temperature of point A in Fig.7.9 at 100Cor below.Please also make sure that the ambient temperature does not exceed85C.Point AFig.7.6 Temperature Measuring Point in the case of Forced Air Cooling(Upper Surface of the Case)Fig.7.9 Temperature Measuring Point in the case of Forced Air CoolingSU . SUC/SUT-57