Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AEA-seriesDerating- AEA800F1 Please satisfy the below temperature at Point A and Point B underthe forced air cooling. The Point A/B position is shown in the next fi gure.- Point A 90C or less and Point B 80C or less at Ta = 50C- Point A 110C or less and Point B 100C or less at Ta = 70C2 The forced air should be given to whole of the product.Point BT201 corePoint ASS102Point ASS102- AEA1000F1 Please satisfy the below temperature at Point A and Point B underthe forced air cooling. The Point A/B position is shown in the next fi gure.- Point A 90C or less and Point B 80C or less at Ta = 50C- Point A 110C or less and Point B 100C or less at Ta = 70C2 The forced air should be given to whole of the product.Point BT201 corePoint ASS102Point ASS102Instruction Manual◆It is neccessary to read the“Instruction Manual”and“Before using our product”before you use our product.Instruction ManualBefore using our producthttps://www.cosel.co.jp/redirect/catalog/en/AEA/https://en.cosel.co.jp/technical/caution/index.htmlAEANOTICEAEABasic Characteristics DataModelCircuit methodSwitchingfrequency[kHz]Inputcurrent[A] *1InrushcurrentprotectionPCB/PatternMaterialSinglesided DoublesidedSeries/Paralleloperation availabilitySeriesoperationParalleloperationAEA600FAEA800FAEA1000FActive filterLLC resonant converters6570 - 2005.7(Peak 11.1)Active filter656.6LLC resonant converters60 - 200(Peak 14.4)Active filter658.4LLC resonant converters70 - 200(Peak 20.6)Relay FR-4 - Yes Yes YesRelay FR-4 - Yes Yes YesRelay FR-4 - Yes Yes Yes*1 The value of input current is at ACIN 100V and rated load (peak).AEA-10? 660 ?