title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
666/916

This page is the summary of page 666 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RAC-DC Power Supplies Medical TypeUMA60FOrdering informationUM A 60 F -O -O1 2 3 4 5 61 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *7E : IEC Class IIT : Terminal blockSN : with Chassis & coverY : with PotentiometerC : with CoatingUMA*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELUMA60F-5UMA60F-7R5UMA60F-12UMA60F-15UMA60F-24UMA60F-36UMA60F-48MAX OUTPUT WATTAGE[W]3041.255452.56061.260DC OUTPUT5V 6A7.5V 5.5A12V 4.5A15V 3.5A24V 2.5A36V 1.7A48V 1.25ASPECIFICATIONSMODELUMA60F-5UMA60F-7R5UMA60F-12UMA60F-15UMA60F-24UMA60F-36UMA60F-48VOLTAGE[V]AC85 - 264 1fCURRENT[A]FREQUENCY[Hz]50/60 (47-63)INPUTEFFICIENCY[%]INRUSH CURRENT[A]LEAKAGE CURRENT[uA] ACIN 264V200maxTOUCH CURRENT[uA] ACIN 264V75maxVOLTAGE[V]57.51215243648CURRENT[A]65.54.53.52.51.71.25WATTAGE[W]3041.255452.56061.260LINE REGULATION[mV]*120max36max48max60max96max144max192maxLOAD REGULATION[mV]*1100max120max120max120max150max240max240maxRIPPLE NOISE [mVp-p] *2 lo=100%150 (Bandwidth 20MHz)OUTPUTTEMPERATURE REGULATION[mV]0~+50C 100max100max120max180max240max360max480maxSTART-UP TIME[ms]ACIN 115VACIN 230V40typHOLD-UP TIME[ms]OUTPUT VOLTAGE ADJUSTMENT RANGE[V]Fixed ("Y"option is available for adjusting output voltage between±10%)OUTPUT VOLTAGE SETTING[V]4.90 to 5.307.20 to 7.8011.50 to 12.5014.40 to 15.6023.00 to 25.0034.50 to 37.5046.00 to 50.00PROTECTIONOVERCURRENT PROTECTION [A]Works over 105% of rating and recovers automaticallyCIRCUIT AND OTHERS OVERVOLTAGE PROTECTION[V]5.75 to 7.008.63 to 10.5013.80 to 16.8017.25 to 21.0027.60 to 33.6041.40 to 50.4055.20 to 67.20INPUT-OUTPUTAC4,000V 1minute, DC500V 100MΩmin(At Room Temperature)2MOPPISOLATIONINPUT-FGAC2,000V 1minute, DC500V 100MΩmin(At Room Temperature)1MOPPOUTPUT-FGAC2,000V 1minute, DC500V 100MΩmin(At Room Temperature)1MOPPOPERATING TEMP.,HUMID. *3-20 to +70C, 20 - 90%RH(Non condensing)ENVIRONMENTIMPACT196.1m/s 2(20G), 11ms, once each X, Y and Z axisSAFETY ANDEMCOTHERSAGENCY APPROVALSANSI/AAMI ES60601-1, EN60601-1 3rd, C-UL(equivalent to CAN/CSA-C22.2 No.60601-1),UL62368-1,EN62368-1, C-UL(equivalent to CAN/CSA-C22.2 No.62368-1), Complies with IEC60335-1EMC EMISSIONComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part 15-B, FCC Part 18-BEMC IMMUNITYComplies with EN61000-4-2, 3, 4, 5, 6, 8, 11HARMONIC ATTENUATOR*4Complies with IEC61000-3-2(Class A)No built-in active PFCCASE SIZE/WEIGHT*550.8X24.2X76.2mm [2.0X0.95X3.0 inches](WXHXD)/ 120g max(with Chassis and cover : 180g max)COOLING METHODConvectionWARRANTY WARRANTY *6 5 years(subject to the operating conditions)*1 Consult us about dynamic load and input response. Measure the output voltage by using theaverage mode of the tester to deal with the burst operation at low (Io=0~20%typ) load.*2 This is the result of measurement of the testing board with capacitors of 47μF and 0.1μFplaced at 150 mm from the output terminals by a 20MHz oscilloscope or a ripple-noisemeter equivalent to Keisoku-GikenRM104.When the load factor is low (Io=0~20%typ), the switching power loss is reduced by burstoperation, which will cause ripple noise to go beyond the specifications.*3 Output power derating is required. Refer to "Derating"*4 Please contact us about another class. When two or more units are operating it may notcomply with the IEC61000-3-2. Please contact us for details.UMA-4 August ? 664 ? 29, 2025*5 Dimensions below PCB are not included.*6 Consult us about details.*7 The listed options may affect the published standard specifications. Please contact us fordetailed product specifications and safety approvals.* All parameters not specially mentioned are measured at ACIN 230V, rated load and 25℃of ambient temperature.* Do not use the power supply in overcurrent conditions or in unspecified input voltageranges. Otherwise the internal components may be damaged.* Parallel operation is not possible with this model.* Acoustic noise may be heard from the power supply when used for pulse load.