title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
668/916

This page is the summary of page 668 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RAC-DC Power Supplies Medical TypeUMA120FOrdering informationUM A 120 F -O -O1 2 3 4 5 61 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *7T : Terminal blockSN : with Chassis & coverC : with CoatingUMA*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELUMA120F-5 -YUMA120F-7R5 -YUMA120F-12 -YUMA120F-15 -YUMA120F-18-YUMA120F-24-YUMA120F-36-YUMA120F-48-YMAX OUTPUT WATTAGE[W]609012097.5108120108120DC OUTPUT5V 12A7.5V 12A12V 10A15V 6.5A18V 6A24V 5A36V 3A48V 2.5ASPECIFICATIONSMODELUMA120F-5 -YUMA120F-7R5 -YUMA120F-12 -YUMA120F-15 -YUMA120F-18-YUMA120F-24-YUMA120F-36-YUMA120F-48-YVOLTAGE[V]AC85 - 264 1fCURRENT[A]FREQUENCY[Hz]50/60(47-63)INPUTPOWR FACTORLEAKAGE CURRENT[uA] ACIN 264V200maxTOUCH CURRENT[uA] ACIN 264V75maxVOLTAGE[V]57.5121518243648CURRENT[A]1212106.56532.5WATTAGE[W]609012097.5108120108120LINE REGULATION[mV]*120max36max48max60max72max96max114max192maxLOAD REGULATION[mV]*1100max100max100max120max150max150max240max240maxOUTPUTRIPPLE NOISE [mVp-p] *2 lo=100% 150 (Bandwidth 20MHz)TEMPERATURE REGULATION [mV] 0~+50C 100max 100max 120max 150max 180max 240max 360max 480maxSTART-UP TIME[ms]ACIN 115VACIN 230V700typHOLD-UP TIME[ms]16typOUTPUT VOLTAGE ADJUSTMENT RANGE[V]4.75 to 5.257.12 to 7.8811.40 to 12.6014.25 to 15.7518.00 to 19.8022.80 to 25.2034.20 to 37.8045.60 to 50.40OUTPUT VOLTAGE SETTING[V]5.00 to 5.137.50 to 7.6912.00 to 12.3015.00 to 15.3818.00 to 18.4524.00 to 24.6036.00 to 36.9048.00 to 49.20PROTECTIONOVERCURRENT PROTECTION [A]Works over 105% of rating and recovers automaticallyCIRCUIT AND OTHERS OVERVOLTAGE PROTECTION[V]5.75 to 7.008.63 to 10.5013.80 to 16.8017.25 to 21.0020.70 to 25.2027.60 to 33.6041.40 to 50.4055.20 to 67.20INPUT-OUTPUTAC4,000V 1minute, DC500V 100MΩmin(At Room Temperature)2MOPPISOLATIONINPUT-FGAC2,000V 1minute, DC500V 100MΩmin(At Room Temperature)1MOPPOUTPUT-FGAC2,000V 1minute, DC500V 100MΩmin(At Room Temperature)1MOPPOPERATING TEMP.,HUMID. *3-20 to +70C, 20 - 90%RH(Non condensing)ENVIRONMENTIMPACT196.1m/s 2(20G), 11ms, once each X, Y and Z axisSAFETY ANDEMCOTHERSAGENCY APPROVALSANSI/AAMI ES60601-1, EN60601-1 3rd, C-UL (equivalent to CAN/CSA-C22.2 No.60601-1),UL62368-1,EN62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1)EMC EMISSIONComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part15-B and FCC Part18-BEMC IMMUNITYComplies with EN61000-4-2, 3, 4, 5, 6, 8, 11HARMONIC ATTENUATOR*4Complies with IEC61000-3-2 Class ACASE SIZE/WEIGHT*550.8X29.0X101.6mm [2.0X1.14X4.0 inches](WXHXD)/ 150g max(with Chassis and cover : 250g max)COOLING METHODConvectionWARRANTY WARRANTY *6 5 years (subject to the operating conditions)*1 Consult us about dynamic load and input response. Measure the output voltage by using theaverage mode of the tester to deal with the burst operation at low (Io=0~10%typ) load.*2 This is the result of measurement of the testing board with capacitors of 47μF and 0.1μFplaced at 150 mm from the output terminals by a 20MHz oscilloscope or a ripple-noisemeter equivalent to Keisoku-GikenRM104.When the load factor is low (Io=0~10%typ), the switching power loss is reduced by burstoperation, which will cause ripple noise to go beyond the specifications.*3 Output power derating is required. Refer to "Derating"*4 Please contact us about another class.UMA-6 August ? 666 ? 29, 2025*5 Dimensions below PCB are not included.*6 Consult us about details.*7 The listed options may affect the published standard specifications. Please contact us fordetailed product specifications and safety approvals.* All parameters not specially mentioned are measured at ACIN 230V, rated load and 25℃of ambient temperature.* Do not use the power supply in overcurrent conditions or in unspecified input voltageranges. Otherwise the internal components may be damaged.* Parallel operation is not possible with this model.* Acoustic noise may be heard from the power supply when used for pulse load.