title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
68/916

This page is the summary of page 68 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RPBA/PBWAC-DC Power Supplies Enclosed TypePBA600FOrdering informationPB A 600 F -5 -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-16-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6C : with CoatingG : Low leakage currentU : Operation stop voltageis set at a lower valueF1 : With Long-Life fanF3 : Reverse air exhausttypeF4 : Low speed fanRefer to instruction manual7.1.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELPBA600F-3R3PBA600F-5PBA600F-7R5PBA600F-12PBA600F-15PBA600F-24PBA600F-36PBA600F-48MAX OUTPUT WATTAGE[W]396600600636645648648624DC OUTPUTACIN 100V 3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27A 36V 18A 48V 13AACIN 200V *3 3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27(31)A 36V 18A 48V 13ASPECIFICATIONSMODELPBA600F-3R3PBA600F-5PBA600F-7R5PBA600F-12PBA600F-15PBA600F-24PBA600F-36PBA600F-48VOLTAGE[V]AC85 - 264 1f or DC120 -350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)CURRENT[A]FREQUENCY[Hz]50/60 (47 -63)ACIN 100V 70typ 75typ 76typ 79typ 79typ 81typ 82typ 81typEFFICIENCY[%]INPUTACIN 200V 72typ 77typ 79typ 82typ 82typ 84typ 84typ 83typPOWER FACTORACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec. to re-start)INRUSH CURRENT[A]ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec. to re-start)LEAKAGE CURRENT[mA]0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC62368-1, DENAN)VOLTAGE[V]3.357.51215243648CURRENT[A]ACIN 100V 120 120 80 53 43 27 18 13ACIN 200V *3 120 120 80 53 43 27(31) 18 13LINE REGULATION[mV]20max20max36max48max60max96max144max192maxLOAD REGULATION[mV]40max40max60max100max120max150max150max300maxRIPPLE[mVp-p]OUTPUT0to +50C *1 120max 120max 150max 150max 150max 150max 200max 200maxRIPPLE NOISE[mVp-p]-20 -0C *1 160max 160max 180max 180max 180max 180max 240max 500maxTEMPERATURE REGULATION[mV]DRIFT[mV]*2 12max20max30max48max60max96max144max192maxSTART-UP TIME[ms]400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.64 -3.963.96 - 6.005.25 - 8.258.25 -13.2010.50 -16.5016.50 - 26.4025.20 - 39.6038.40 -56.00OUTPUT VOLTAGE SETTING[V]3.30 -3.405.00 - 5.157.50 - 7.8012.00 -12.4815.00 -15.6024.00 - 24.9636.00 - 37.4448.00 -49.92OVERCURRENT PROTECTIONWorks over 105% of rated current or 101% of peak current and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V] *4 Vo+0.66 -1.32Vo+1.0 - 2.0Vo+1.5 - 3.0Vo+2.4 - 4.8Vo+3.0 - 6.0Vo+4.8 - 9.6Vo+7.2 - 14.4Vo+4.8 - 12.0CIRCUIT AND OPERATING INDICATIONLED (Green)OTHERSREMOTE SENSINGProvidedREMOTE ON/OFFProvidedISOLATIONOUTPUT-RC-AUXOPERATING TEMP.,HUMID.AND ALTITUDE-20 to +71C (Refer to“Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxENVIRONMENTVIBRATION10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Yand Z axisIMPACT196.1m/s2 (20G), 11ms, once each X, Y and Z axisSAFETY AND AGENCY APPROVALS (At only ACinput)UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 *7OTHERS*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN:RM101).*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manualin detail.*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltageprotection circuit is please contact us for details.PBA/PBW-18? 66 ?*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.*7 Please contact us about class C.* A sound may occur from power supply at pulse loading.