title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
698/916

This page is the summary of page 698 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Medical TypeGMA300FOrdering informationGM A 300 F -OO -O1 2 3 4 5 6GMARThis power supply is manufactured using SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELGMA300F-12GMA300F-24GMA300F-48GMA300F-56MAX OUTPUT WATTAGE[W]300300302.4302.4DC OUTPUT12V 25A24V 12.5A48V 6.3A56V 5.4ASPECIFICATIONSMODELGMA300F-12GMA300F-24GMA300F-48GMA300F-56VOLTAGE[V]*3AC85 - 264 1f (Output derating is required at AC85V - 115V. See“Derating”)CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 66)ACIN 115V 90typ 91typ 91typ 91typEFFICIENCY[%]INPUTACIN 230V 92typ 93typ 93typ 93typPOWER FACTORACIN 115V0.95typ(Io=100%) ACIN 230V0.90typACIN 115V 30typ (Io=100%) (At cold start, Ta=25℃)INRUSH CURRENT[A]ACIN 230V 60typ (Io=100%) (At cold start, Ta=25℃)LEAKAGE CURRENT[mA]0.13 / 0.30max (ACIN 100/240V 60Hz, Io=100%, According to IEC60601-1)VOLTAGE[V]12244856CURRENT[A]2512.56.35.4LINE REGULATION[mV]*448max96max192max192maxLOAD REGULATION[mV] *4100max150max240max240maxRIPPLE[mVp-p]*10 to +50C 240max 240max 400max 400max-20 to 0C 320max 320max 500max 500maxOUTPUTDRIFT[mV]*248max96max192max192maxSTART-UP TIME[ms]400typ (ACIN 115V, Io=100%)*Start-up time is 900ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]16typ (ACIN 115V, Io=85%) / 12typ (ACIN 115V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]11.40~13.2022.80~26.4045.60~52.8052.00~56.00OUTPUT VOLTAGE SETTING[V]12.00~12.4824.00~24.9648.00~49.9255.00~56.00OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V]13.80 to 16.8027.60 to 33.6055.20 to 67.2060.00 to 70.50CIRCUIT AND AUX1 (12V1A)OptionalOTHERSAUX2 (5V1A)OptionalREMOTE ON/OFFOptionalINPUT-OUTPUT-RC-AUX *7AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOPPISOLATIONOUTPUT-RC-AUX*7AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-20 to +70C, 20 - 90%RH (Non condensing), 5,000m (16,000feet) max *3 *8ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL62368-1, ANSI/AAMI ES60601-1, C-UL, EN62368-1, EN60601-1 3rd, Complies with IEC60601-1-2 4th Ed.NOISECONDUCTED NOISEComplies with FCC Part15 classB, VCCI-B, CISPR32-B, EN55011-B, EN55032-BREGULATIONSHARMONIC ATTENUATOR *5 Complies with IEC61000-3-2 (class A)OTHERS*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm fromoutput terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103).*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25℃, withthe input voltage held constant at the rated input/output.*3 Refer to“Derating”*4 Please contact us about dynamic load and input response.*5 Please contact us about another class.Example recommended EMI/EMC filterEAC-06-472High voltage pulse noise type : EAP seriesLow leakage current type : EAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.*6 Specification is changed at option, refer to Instruction Manual.*7 Applicable when AUX and remote control (optional) is added.*8 Please contact us about for more detail.* To meet the specifications. Do not operate over-loaded condition.* Parallel operation is not possible.* Sound noise may be generated by power supply in case of pulse load.* Substrate bottom has a Electric potential. Insulation is required.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6C : with CoatingJ1 : Input connectorVH (J.S.T.) connector typeJ3 : Horizontal input connectorVH (J.S.T.) connector typeR3 : with Subfeatures(5V1A AUX, 12V1A AUX,Remote ON/OFF)Specification changes when optionsare added. Please refer to theinstruction manual for more detail.GMA-2? 696 ?