Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
RPBA/PBWAC-DC Power Supplies Enclosed TypePBA1000FOrdering informationPB A 1000 F -5 -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-20-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6C : with CoatingG : Low leakage currentU : Operation stop voltageis set at a lower valueF1 : With Long-Life fanF3 : Reverse air exhausttypeF4 : Low speed fanRefer to instruction manual7.1.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELPBA1000F-3R3PBA1000F-5PBA1000F-7R5PBA1000F-12PBA1000F-15PBA1000F-24PBA1000F-36PBA1000F-48MAX OUTPUT WATTAGE[W]6601000100510561050105610441056DC OUTPUTACIN 100V 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44A 36V 29A 48V 22AACIN 200V *3 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44(51)A 36V 29A 48V 22ASPECIFICATIONSMODELPBA1000F-3R3PBA1000F-5PBA1000F-7R5PBA1000F-12PBA1000F-15PBA1000F-24PBA1000F-36PBA1000F-48VOLTAGE[V]AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)CURRENT[A]FREQUENCY[Hz]50/60 (47 - 63)ACIN 100V 74typ 79typ 80typ 82typ 82typ 84typ 84typ 84typEFFICIENCY[%]INPUTACIN 200V 76typ 81typ 83typ 84typ 84typ 86typ 86typ 86typPOWER FACTORACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)INRUSH CURRENT[A]ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)LEAKAGE CURRENT[mA]0.5/1.0max (ACIN 100V/240V 60Hz, Io=100%, According to IEC62368-1, DENAN)VOLTAGE[V]3.357.51215243648CURRENT[A]ACIN 100V 200 200 134 88 70 44 29 22ACIN 200V *3 200 200 134 88 70 44(51) 29 22LINE REGULATION[mV]20max20max36max48max60max96max144max192maxLOAD REGULATION[mV]40max40max60max100max120max150max150max300maxRIPPLE[mVp-p]OUTPUT0 to +50C *1 120max 120max 150max 150max 150max 150max 200max 200maxRIPPLE NOISE[mVp-p]-20 - 0C *1 160max 160max 180max 180max 180max 180max 240max 500maxTEMPERATURE REGULATION[mV]DRIFT[mV]*2 12max20max30max48max60max96max144max192maxSTART-UP TIME[ms]400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]20typ (ACIN 100/200V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.64 - 3.963.96 - 6.005.25 - 8.258.25 - 13.2010.50 - 16.5016.50 - 26.4025.20 - 39.6038.40 - 56.00OUTPUT VOLTAGE SETTING[V]3.30 - 3.405.00 - 5.157.50 - 7.8012.00 - 12.4815.00 - 15.6024.00 - 24.9636.00 - 37.4448.00 - 49.92OVERCURRENT PROTECTIONWorks over 105% of rated current or 101% of peak current and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V] *4 Vo+0.66 - 1.32Vo+1.0 - 2.0Vo+1.5 - 3.0Vo+2.4 - 4.8Vo+3.0 - 6.0Vo+4.8 - 9.6Vo+7.2 - 14.4Vo+4.8 - 12.0CIRCUIT AND OPERATING INDICATIONLED (Green)OTHERSREMOTE SENSINGProvidedREMOTE ON/OFFProvidedISOLATIONOUTPUT-RC-AUXOPERATING TEMP.,HUMID.AND ALTITUDE-20 to +71C (Refer to“Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxENVIRONMENTVIBRATION10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT196.1m/s2 (20G), 11ms, once each X, Y and Z axisSAFETY AND AGENCY APPROVALS (At only AC input)UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2*7OTHERS*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN:RM101).Ripple and ripple noise is measured on measuring board with capacitor of 22mF within150mm from the output terminal.*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manualin detail.PBA/PBW-20? 68 ?*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltageprotection circuit is please contact us for details.*5 Derating is required.Consult us for details.*6 Please contact us about safety approvals for the model with option.*7 Please contact us about class C.* A sound may occur from power supply at pulse loading.