Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Medical TypeGHA300FOrdering informationGH A 300 F -OO -O1 2 3 4 5 6GHARSpecification is changed atoption, refer to InstructionThis power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care manual.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELGHA300F-12GHA300F-24GHA300F-48MAX OUTPUT WATTAGE[W]300300302.4Forced air at 50C12V 25A24V 12.5A48V 6.3ADC OUTPUTConvectionat 40C 12V 8.4A 24V 4.2A 48V 2.1Aat 50C 12V 4.5A 24V 2.2A 48V 1.1ASPECIFICATIONSExample recommended EMI/EMC filterEAC-10-472High voltage pulse noise type : EAP seriesLow leakage current type : EAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6T3 : mounting hole M3J1 : J.S.T.connector typeJ3 : Horizontal input connectorJ.S.T.connector typeR3 : with Subfeatures( 5VAUX,12VAUX,Remote,Power good)(Molexconnector type)*with friction locks,J2R3MODELGHA300F-12GHA300F-24GHA300F-48VOLTAGE[V]AC90 - 264 1f (output derating is required at AC90V -115V *3)CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 120V 89typ 90typ 90typEFFICIENCY[%]INPUTACIN 230V 91typ 92typ 92typPOWER FACTORACIN 120V0.95typ(Io=100%) ACIN 230V0.90typACIN 120V 20typ (Io=100%) (At cold start) (Ta=25C)INRUSH CURRENT[A]ACIN 230V 40typ (Io=100%) (At cold start) (Ta=25C)LEAKAGE CURRENT[mA]0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1)VOLTAGE[V]122448CURRENT[A]LINE REGULATION[mV]*448max96max192maxLOAD REGULATION[mV] *4100max150max240maxRIPPLE[mVp-p]*10 to +50C 240max 240max 300max-20 to 0C 320max 320max 400maxOUTPUTRIPPLE NOISE[mVp-p]*10 to +50C 300max 300max 480max-20 to 0C 360max 360max 500maxTEMPERATURE REGULATION[mV]0 to +50C 120max 240max 480max-20 to +50C 150max 290max 600maxDRIFT[mV]*248max96max192maxSTART-UP TIME[ms]500typ (ACIN 120V, Io=100%)HOLD-UP TIME[ms]16typ (ACIN 120V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]10.80 to 13.2021.60 to 26.4043.20 to 52.80OUTPUT VOLTAGE SETTING[V]12.00 to 12.4824.00 to 24.9648.00 to 49.92OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyOVERVOLTAGE PROTECTION[V] 13.80 to 16.80 27.60 to 33.60 55.20 to 67.20PROTECTIONAUX1 (12V1A)OptionalCIRCUIT ANDAUX2 (5V1A)OptionalOTHERSREMOTE ON/OFF OptionalPowerGoodOptionalINPUT-OUTPUT-RC-AUX *7AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOPPISOLATIONOUTPUT-RC-AUX*7AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *3ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisUL60950-1, ANSI/AAMI ES60601-1, C-UL(CSA60950-1, CAN/CSA60601-1), EN62368-1, EN60601-1 3rd,SAFETY AND AGENCY APPROVALSComplies with DEN-AN, IEC60601-1-2 4th Ed.NOISECONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATOR Complies with IEC61000-3-2 (class A) *5OTHERS*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm fromoutput terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103).*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, withthe input voltage held constant at the rated input/output.*3 Derating is required.*4 Please contact us about dynamic load and input response.*5 Please contact us about another class.*6 Specification is changed at option, refer to Instruction Manual.*7 Applicable when AUX and remote control (optional) is added.* To meet the specifications. Do not operate over-loaded condition.* Sound noise may be generated by power supply in case of pulse load.* Parallel operation is not possible.* Forced air cooling is required to output up to MAX OUTPUT WATTAGE.* Bottom layer P.C.B has electric potential which is required isolation from FG by clearance orcreepage as the safety design issue.GHA-2? 702 ?