title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
708/916

This page is the summary of page 708 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Medical TypeGHA700FOrdering informationGH A 700 F -OO -O1 2 3 4 5 6GHA2MOPPGHA-6RThis power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *1C : with CoatingE : IEC ClassⅡR3 : With Subfeatures( 5VAUX, 12VAUX*,Remote, Power good)*Excluding GHA700F-12T3 : mounting hole M3U1 : can attach an externalcapacitor unitSpecification is changed atoption, refer to Instructionmanual.MODELGHA700F-12-J1GHA700F-24-J1GHA700F-30-J1GHA700F-48-J1GHA700F-56-J1MAX OUTPUT WATTAGE[W]650.4700.8699.0700.8700.0Forced air at 50C12V 54.2A24V 29.2A30V 23.3A48V 14.6A56V 12.5ADC OUTPUTat 30C 12V 33.4A 24V 16.7A 30V 13.4A 48V 8.4A 56V 7.2AConvectionat 50C 12V 22.2A 24V 11.1A 30V 8.9A 48V 5.6A 56V 4.8Aconduction cooling at 50C12V 33.4A24V 16.7A30V 13.4A48V 8.4A56V 7.2ASPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERSExample recommended EMI/EMC filterEAC-16-472High voltage pulse noise type : EAP seriesLow leakage current type : EAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.MODELGHA700F-12-J1GHA700F-24-J1GHA700F-30-J1GHA700F-48-J1GHA700F-56-J1VOLTAGE[VAC]85 - 264 1f (Refer to“Derating”and Instruction Manual 1.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (45 - 66)EFFICIENCY[%]POWER FACTORACIN 115V0.95typ(Po=700W) ACIN 230V0.90typINRUSH CURRENT[A] ACIN 115V20typ (At rated load) (At cold start) (Ta=25C)*2 ACIN 230V40typ (At rated load) (At cold start) (Ta=25C)EARTH LEAKAGE CURRENT[μA]100/200max (ACIN 100/264V 60Hz, At rated load, According to IEC60601-1)TOUCH CURRENT[μA]100max (ACIN 264V 60Hz, At rated load, According to IEC60601-1)VOLTAGE[VAC]1224304856Forced air54.229.223.314.612.5CURRENT[A]Convection33.416.713.48.47.2conduction cooling33.416.713.48.47.2LINE REGULATION[mV]*348max96max120max192max192maxLOAD REGULATION[mV] *3 *9100max150max180max240max240maxRIPPLE[mVp-p]0 to +50C240max300max350max550max600max*4 *10-20C to +0C320max400max500max700max750maxRIPPLE NOISE[mVp-p]0 to +50C300max400max450max650max700max*4 *10-20C to +0C360max500max600max800max850max0 to +50C 120max 240max 300max 480max 600maxTEMPERATURE REGULATION[mV]-20C to +50C 150max 290max 360max 600max 720maxDRIFT[mV]*548max96max120max192max192maxSTART-UP TIME[ms]500typ (ACIN 115V, At rated load)HOLD-UP TIME[ms]12typ (ACIN 115V, At rated load)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]11.40 to 13.2022.80 to 26.4028.50 to 33.0045.60 to 52.8053.20 to 61.60OUTPUT VOLTAGE SETTING[V] 12.00 to 12.4824.00 to 24.9630.00 to 31.2048.00 to 49.9256.00 to 58.24OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automatically *6OVERVOLTAGE PROTECTION[V]13.80 to 16.8027.60 to 33.6034.50 to 42.0055.20 to 67.2064.40 to 78.40AUX1 (12V1A)Optional (Refer to Instruction Manual 6.1) (Excluding GHA700F-12)AUX2 (5V1A)Optional (Refer to Instruction Manual 6.1)REMOTE ON/OFFOptional (Refer to Instruction Manual 6.1)POWER GOODOptional (Refer to Instruction Manual 6.1)INPUT-OUTPUT-RC-AUX *7 AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOPPINPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOPPISOLATIONOUTPUT-RC-AUX-FG *7 AC1,500V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOPPOUTPUT-RC-AUX *7 AC500V 1minute, Cutoff current=25mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +80C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -30 to +80C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) maxENVIRONMENTVIBRATION10 - 55Hz, 19.6m/s 2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisUL62368-1, ANSI/AAMI ES60601-1,C-UL (equivalent to CAN/CSA-C22.2 No.62368-1, CAN/CSA-C22.2 No.60601-1), EN62368-1, EN60601-1 3rd,SAFETY AND AGENCY APPROVALSComplies with IEC60601-1-2 4th Ed., EN61558-2-16 (OVCⅢ) , DEN-ANNOISECONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR32-B, EN55011-B, EN55032-BREGULATIONSHARMONIC ATTENUATOR *8 Complies with IEC61000-3-2 (class A)CASE SIZE/WEIGHT 76.2X38.1X127mm [3X1.5X5] (WXHXD) / 570g maxOTHERSCOOLING METHOD Convection, Forced air (Require external fan), Conduction cooling? 706 ?■BF