title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
712/916

This page is the summary of page 712 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Medical TypeGHA500F-SNFOrdering informationGH A 500 F -OO -SNFO1 2 3 4 5 6RExample recommended EMI/EMC filterEAC-10-472High voltage pulse noise type : EAP seriesLow leakage current type : EAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6J1 : CN501PHconnector type(J.S.T.)J2 : CN501Friction locks connectortype (Molex)P : Parallel OperationRefer to the instruction manual6.1.GHA*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELGHA500F-12-SNFGHA500F-15-SNFGHA500F-24-SNFGHA500F-30-SNFGHA500F-48-SNFGHA500F-56-SNFMAX OUTPUT WATTAGE[W]450501504501504504DC OUTPUTForced air +50C12V 37.5A15V 33.4A24V 21.0A30V 16.7A48V 10.5A56V 9.0ASPECIFICATIONSMODELGHA500F-12-SNFGHA500F-15-SNFGHA500F-24-SNFGHA500F-30-SNFGHA500F-48-SNFGHA500F-56-SNFVOLTAGE[V]AC90 - 264 1f (output derating is required at AC90V -115V *3)CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 120V 87typ 89typ 89typ 89typ 89typ 89typEFFICIENCY[%]INPUTACIN 230V 89typ 91typ 91typ 91typ 91typ 91typPOWER FACTORACIN 120V0.95typ(Io=100%) ACIN 230V0.90typACIN 120V 20typ (Io=100%) (At cold start) (Ta=25C)INRUSH CURRENT[A]ACIN 230V 40typ (Io=100%) (At cold start) (Ta=25C)LEAKAGE CURRENT[mA]0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1)VOLTAGE[V]121524304856CURRENT[A]Forced air37.533.421.016.710.59.0LINE REGULATION[mV]*448max60max96max120max192max192maxLOAD REGULATION[mV] *4100max120max150max180max240max240maxRIPPLE[mVp-p]*10 to +50C 240max 240max 240max 300max 300max 400max-20 - 0C 320max 320max 320max 400max 400max 500max0 to +50C 300max 300max 300max 480max 480max 500maxRIPPLE NOISE[mVp-p]*1OUTPUT-20 - 0C 360max 360max 360max 500max 500max 580maxTEMPERATURE REGULATION[mV]0 to +50C 120max 150max 240max 300max 480max 480max-20 to +50C 150max 180max 290max 360max 600max 600maxDRIFT[mV]*248max60max96max120max192max192maxSTART-UP TIME[ms]500typ (ACIN 120V, Io=100%)HOLD-UP TIME[ms]16typ (ACIN 120V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]10.80 to 13.2013.50 to 16.5021.60 to 26.4027.00 to 31.5043.20 to 52.8052.00 to 56.00OUTPUT VOLTAGE SETTING[V]12.00 to 12.4815.00 to 15.3024.00 to 24.9630.00 to 31.2048.00 to 49.9255.00 to 56.00PROTECTIONCIRCUIT ANDOTHERSGHA-10OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automatically *7OVERVOLTAGE PROTECTION[V]13.80 to 16.8017.25 to 21.0027.60 to 33.6034.50 to 42.0055.20 to 67.2060.00 to 69.00AUX112V 0.5AAUX25V 1AREMOTE ON/OFFPossible, AUX2 is availablePowerGoodOpen collectorINPUT-OUTPUT-RC-AUXAC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOPPISOLATIONOUTPUT-RC-AUXAC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *3ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisUL60950-1, ANSI/AAMI ES60601-1, C-UL(CSA60950-1, CAN/CSA60601-1), EN62368-1, EN60601-1 3rd,SAFETY AND AGENCY APPROVALSComplies with DEN-AN, IEC60601-1-2 4th Ed.NOISECONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATOR Complies with IEC61000-3-2 (class A) *5OTHERS*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm fromoutput terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103).*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, withthe input voltage held constant at the rated input/output.*3 Refer to“Derating”.*4 Please contact us about dynamic load and input response.? 710 ?*5 Please contact us about another class.*6 Specification is changed at option, refer to Instruction Manual.*7 When output current more than rated, output will shut down after 5 seconds or more.Recycle input after 3 minutes to reset the protection.* To meet the specifications. Do not operate over-loaded condition.* Sound noise may be generated by power supply in case of pulse load.* Parallel operation is available with -P option. Refer to 5.1on the instruction manual.