title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
726/916

This page is the summary of page 726 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Medical TypePJMA1500FOrdering informationPJM A 1500 F -O -O1 2 3 4 5 62MOPPRExample recommended EMI/EMC filterNAC-20-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series1 Series name2 Single output3Output wattage4Universal input5Output voltage6Optional *8C: with CoatingG: Low leakage currentV: External potentiometer foroutput voltage adjustmentW: Parallel operation, LV alarmand Remote sensing(Except 48V)W1: LV alarm and Remote sensingR: Remote on/off(Required external powersource)F4: Low speed fanSee 5.1 in Instruction Manual.PJMA*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.SPECIFICATIONSMODELPJMA1500F-12PJMA1500F-24PJMA1500F-36PJMA1500F-48VOLTAGE[V]AC85 - 264 1f (Output derating is required at AC85V - 115V. Refer to“Derating”and instruction manual 1.1)ACIN 100V18typ (Io=90%)CURRENT[A]ACIN 115V16typ (Io=100%)ACIN 230V8typ (Io=100%)FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 100V81typ (Io=90%)84typ (Io=90%)84typ (Io=90%)84typ (Io=90%)EFFICIENCY[%]ACIN 115V82typ (Io=100%)85typ (Io=100%)85typ (Io=100%)84typ (Io=100%)INPUTACIN 230V85typ (Io=100%)88typ (Io=100%)88typ (Io=100%)87typ (Io=100%)ACIN 100V0.98typ (Io=90%)POWER FACTORACIN 115V0.98typ (Io=100%)ACIN 230V0.95typ (Io=100%)ACIN 100V15/30typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)INRUSH CURRENT[A]ACIN 115V15/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)ACIN 230V30/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)LEAKAGE CURRENT[mA]0.3max (ACIN 240V, 60Hz, Io=100%)VOLTAGE[V]12243648CURRENT[A]ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to“Derating”)ACIN 115V-264V 125 64 42 32WATTAGE[W]ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to“Derating”)ACIN 115V-264V 1500 1536 1512 1536LINE REGULATION[mV]*248max96max144max192maxLOAD REGULATION[mV]*2100max150max150max300maxRIPPLE[mVp-p]0 to +50C180max120max150max200maxOUTPUT*1 -20 to 0C 240max 160max 200max 500maxRIPPLE NOISE[mVp-p] 0 to +50C 210max 150max 200max 300max*1-20 to 0C270max270max240max600max0 to +50C 120max 240max 360max 480maxTEMPERATURE REGULATION[mV]-20 to +50C 180max 290max 440max 600maxDRIFT[mV]*348max96max144max192maxSTART-UP TIME[ms]800typ (ACIN 115V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 115V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]10.80 to 13.5020.40 to 28.5030.60 to 40.8040.80 to 55.20OUTPUT VOLTAGE SETTING[V]12.00 to 12.4824.00 to 24.9636.00 to 37.4448.00 to 49.92OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyPROTECTIONOVERVOLTAGE PROTECTION[V]14.40 to 17.4028.80 to 34.8043.20 to 52.2057.00 to 67.20CIRCUIT ANDOPERATING INDICATIONLED (Green)OTHERSREMOTE SENSINGOptional (Option -W, -W1)REMOTE ON/OFFOptional (Required external power source. Option -R)INPUT-OUTPUTAC4,000V 1minute, Cutoff=20mA, 2MOPP DC500V 50MW min (At room temperature)ISOLATIONOUTPUT-RCAC500V 1minute, Cutoff=20mA, DC500V 50MW min (At room temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *4-20 to +70C (Refer to“Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axesSAFETY ANDAGENCY APPROVALSANSI/AAMI ES60601-1, C-UL(CAN/CSA-C22.2 No. 60601-1), EN60601-1 3rdNOISECONDUCTED NOISEComplies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part 15-B. FCC Part 18-BREGULATIONSHARMONIC ATTENUATOR *5Complies with IEC61000-3-2 class APJMA-8 May ? 724 09, ? 2025