title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
744/916

This page is the summary of page 744 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Medical TypePMA15FOrdering informationPM A 15 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAM-04-000Low leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5T : Vertical terminal blockT1 : Horizontal terminal blockN : with CoverJ1 : VH(J.S.T.)connector typePMAMODELPMA15F-3R3PMA15F-5PMA15F-12PMA15F-15PMA15F-24MAX OUTPUT WATTAGE[W]9.91515.61516.8DC OUTPUT3.3V 3A5V 3A12V 1.3A15V 1A24V 0.7ASPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERSPMA-2Horizontal terminal block(option : -T1)MODELPMA15F-3R3PMA15F-5PMA15F-12PMA15F-15PMA15F-24VOLTAGE[V]AC85 - 264 1f (Refer to the Instruction Manual 1.1 and“Derating”) *3CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 440)EFFICIENCY[%]ACIN 100V 15typ (Io=100%) (At cold start)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%) (At cold start)LEAKAGE CURRENT[mA]0.05/0.10max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1)VOLTAGE[V]3.35121524CURRENT[A]3.03.01.31.00.7LINE REGULATION[mV]20max20max48max60max96maxLOAD REGULATION[mV]40max40max100max120max150maxRIPPLE[mVp-p]0 to +50C80max80max120max120max120max*1-10 - 0C140max140max160max160max160maxRIPPLE NOISE[mVp-p]*1Vertical terminal block(option : -T)0 to +50C120max120max150max150max150max-10 - 0C160max160max180max180max180maxTEMPERATURE REGULATION[mV]DRIFT[mV]*220max20max48max60max96maxSTART-UP TIME[ms]200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 to 3.604.50 to 5.5010.00 to 13.2013.20 to 18.0019.20 to 27.00OUTPUT VOLTAGE SETTING[V]3.30 to 3.405.00 to 5.1512.00 to 12.4815.00 to 15.6024.00 to 24.96OVERCURRENT PROTECTIONStandard typeWorks over 105% of rating and recovers automaticallyOVERVOLTAGE PROTECTION[V]4.00 to 5.255.75 to 7.0015.00 to 18.0020.00 to 25.0030.00 to 37.00OPERATING INDICATIONLED (Green)REMOTE ON/OFFNot providedINPUT-OUTPUTAC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT-FGAC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max *3ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1NOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Class A) *6 (Not built-in to active filter *4)OTHERS*1Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101).*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3Refer to“Derating”.*4When two or more units are used, they may not comply with the harmonic attenuator. Pleasecontact us for details.with Cover(option : -N)*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.? 742 ?*5 Please contact us about safety approvals for the model with option.*6 Please contact us about another class.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.Specification is changed atoption, refer to InstructionManual.