Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Medical TypePMA30FOrdering informationPM A 30 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAM-04-000Low leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5T : Vertical terminal blockT1 : Horizontal terminal blockN : with CoverJ1 : VH(J.S.T.)connector typePMAMODELPMA30F-3R3PMA30F-5PMA30F-12PMA30F-15PMA30F-24MAX OUTPUT WATTAGE[W]19.830303031.2DC OUTPUT3.3V 6A5V 6A12V 2.5A15V 2A24V 1.3ASPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERSPMA-4Horizontal terminal block(option : -T1)MODELPMA30F-3R3PMA30F-5PMA30F-12PMA30F-15PMA30F-24VOLTAGE[V]AC85 - 264 1f (Refer to the Instruction Manual 1.1 and“Derating”) *3CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 440)EFFICIENCY[%]ACIN 100V 15typ (Io=100%) (At cold start)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%) (At cold start)LEAKAGE CURRENT[mA]0.05 / 0.10max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1)VOLTAGE[V]3.35121524CURRENT[A]6.06.02.52.01.3LINE REGULATION[mV]20max20max48max60max96maxLOAD REGULATION[mV]40max40max100max120max150maxRIPPLE[mVp-p]0 to +50C80max80max120max120max120max*1-10 - 0C140max140max160max160max160maxRIPPLE NOISE[mVp-p]*1Vertical terminal block(option : -T)0 to +50C120max120max150max150max150max-10 - 0C160max160max180max180max180maxTEMPERATURE REGULATION[mV]DRIFT[mV]*220max20max48max60max96maxSTART-UP TIME[ms]200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 to 3.604.50 to 5.5010.00 to 13.2013.20 to 18.0019.20 to 27.00OUTPUT VOLTAGE SETTING[V]3.30 to 3.405.00 to 5.1512.00 to 12.4815.00 to 15.6024.00 to 24.96OVERCURRENT PROTECTIONStandard typeWorks over 105% of rating and recovers automaticallyOVERVOLTAGE PROTECTION[V]4.00 to 5.255.75 to 7.0015.00 to 18.0020.00 to 25.0030.00 to 37.00OPERATING INDICATIONLED (Green)REMOTE ON/OFFNot providedINPUT-OUTPUTAC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT-FGAC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *3ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1NOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 (Class A) *6 (Not built-in to active filter *4)OTHERS*1Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101).*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3Refer to“Derating”.*4When two or more units are used, they may not comply with the harmonic attenuator. Pleasecontact us for details.with Cover(option : -N)*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.? 744 ?*5 Please contact us about safety approvals for the model with option.*6 Please contact us about another class.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.Specification is changed atoption, refer to InstructionManual.