Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Medical TypePMA60FOrdering informationPM A 60 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAM-04-000Low leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5T : Vertical terminal blockT1 : Horizontal terminal blockN : with CoverJ1 : VH(J.S.T.)connector typeR : with Remote ON/OFFPMAMODELPMA60F-3R3PMA60F-5PMA60F-12PMA60F-15PMA60F-24MAX OUTPUT WATTAGE[W]39.660606060DC OUTPUT3.3V 12A5V 12A12V 5A15V 4A24V 2.5ASPECIFICATIONSMODELPMA60F-3R3PMA60F-5PMA60F-12PMA60F-15PMA60F-24VOLTAGE[V]AC85 - 264 1f (Refer to the Instruction Manual 1.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 100V 77typ 80typ 80typ 81typ 81typEFFICIENCY[%]INPUTACIN 200V 78typ 83typ 82typ 83typ 83typPOWER FACTORACIN 100V0.98typ(Io=100%)ACIN 200V0.85typ0.90typACIN 100V 15typ (Io=100%) (At cold start)INRUSH CURRENT[A]ACIN 200V 30typ (Io=100%) (At cold start)LEAKAGE CURRENT[mA]0.09 / 0.18max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1)VOLTAGE[V]3.35121524CURRENT[A]12.012.05.04.02.5LINE REGULATION[mV]20max20max48max60max96maxLOAD REGULATION[mV]40max40max100max120max150maxRIPPLE[mVp-p]0 to +50C80max80max120max120max120max*1-10 - 0C140max140max160max160max160maxRIPPLE NOISE[mVp-p]0 to +50C120max120max150max150max150maxOUTPUT*1-10 - 0C160max160max180max180max180maxTEMPERATURE REGULATION[mV]DRIFT[mV]*220max20max48max60max96maxSTART-UP TIME[ms]250typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 to 3.604.50 to 5.5010.00 to 13.2013.20 to 18.0019.20 to 27.00OUTPUT VOLTAGE SETTING[V]3.30 to 3.405.00 to 5.1512.00 to 12.4815.00 to 15.6024.00 to 24.96PROTECTIONCIRCUIT ANDOTHERSPMA-6Horizontal terminal block(option : -T1)Vertical terminal block(option : -T)Standard typeOVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyOVERVOLTAGE PROTECTION[V]4.00 to 5.255.75 to 7.0015.00 to 18.0020.00 to 25.0030.00 to 37.00OPERATING INDICATIONLED (Green)REMOTE ON/OFFOptional (Required external power source)INPUT-OUTPUT . RC*3AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT . RC-FG*3AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *4ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1NOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 *6OTHERS*1Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101).*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3Applicable when Remote ON/OFF (optional) is added. RC is insulated with input, output and FG.*4Refer to“Derating”.*5Please contact us about safety approvals for the model with option.with Cover(option : -N)*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.? 746 ?*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.Specification is changed atoption, refer to InstructionManual.