Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies Medical TypePMA100FOrdering informationPM A 100 F -O -O1 2 3 4 5 6RExample recommended EMI/EMC filterNAM-06-000Low leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *5T : Vertical terminal blockT1 : Horizontal terminal blockN : with CoverJ1 : VH(J.S.T.)connector typeR : with Remote ON/OFFPMAMODELPMA100F-3R3PMA100F-5PMA100F-12PMA100F-24PMA100F-48MAX OUTPUT WATTAGE[W]66100102108100.8DC OUTPUT3.3V 20A5V 20A12V 8.5A24V 4.5A48V 2.1ASPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERSPMA-8Horizontal terminal block(option : -T1)MODELPMA100F-3R3PMA100F-5PMA100F-12PMA100F-24PMA100F-48VOLTAGE[V]AC85 - 264 1f (Refer to the Instruction Manual 1.1)CURRENT[A]FREQUENCY[Hz]50 / 60 (47 - 63)EFFICIENCY[%]POWER FACTORACIN 100V0.98typ(Io=100%)ACIN 200V0.85typ0.90typACIN 100V 20typ (Io=100%) (At cold start)INRUSH CURRENT[A]ACIN 200V 40typ (Io=100%) (At cold start)LEAKAGE CURRENT[mA]0.09 / 0.18max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1)VOLTAGE[V]3.35122448CURRENT[A]20.020.08.54.52.1LINE REGULATION[mV]20max20max48max96max192maxLOAD REGULATION[mV]40max40max100max150max240maxRIPPLE[mVp-p]0 to +50C80max80max120max120max150max*1-10 - 0C140max140max160max160max200maxRIPPLE NOISE[mVp-p]*1Vertical terminal block(option : -T)0 to +50C120max120max150max150max250max-10 - 0C160max160max180max180max300maxTEMPERATURE REGULATION[mV]DRIFT[mV]*220max20max48max96max192maxSTART-UP TIME[ms]250typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]2.85 to 3.604.50 to 5.5010.00 to 13.2019.20 to 27.0039.00 to 53.00OUTPUT VOLTAGE SETTING[V]3.30 to 3.405.00 to 5.1512.00 to 12.4824.00 to 24.9648.00 to 49.92OVERCURRENT PROTECTIONStandard typeWorks over 105% of rating and recovers automaticallyOVERVOLTAGE PROTECTION[V]4.00 to 5.255.75 to 7.0015.00 to 18.0030.00 to 37.0058.00 to 65.00OPERATING INDICATIONLED (Green)REMOTE ON/OFFOptional (Required external power source)INPUT-OUTPUT . RC*3AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)OUTPUT . RC-FG*3AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *4ENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axisSAFETY ANDAGENCY APPROVALSUL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1NOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2 *6OTHERS*1Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101).*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.*3Applicable when Remote ON/OFF (optional) is added. RC is insulated with input, output and FG.*4Refer to“Derating”.*5Please contact us about safety approvals for the model with option.with Cover(option : -N)*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.? 748 ?*6 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.Specification is changed atoption, refer to InstructionManual.