title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
78/916

This page is the summary of page 78 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

RPBA/PBWAC-DC Power Supplies Enclosed TypePBW30FOrdering informationPB W 30 F -O -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-06-4721 Series name2 Dual output3 Output wattage4 Universal input5 Output voltage6 Optional *10C : with CoatingG : Low leakage currentHigh voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.E : Low leakage currentand EMI class AT : Vertical terminal blockJ1 : VH (J.S.T.) connector typeN : with CoverN1 : with DIN railV : Output voltage settingpotentiometer externallyMODELPBW30F-5PBW30F-12PBW30F-15MAX OUTPUT WATTAGE[W]*5 1531.230.0VOLTAGE[V] *6 t5 ( +10 )t12 ( +24 )t15 ( +30 )DC OUTPUTCURRENT1[A]1.51.31.0CURRENT2[A]*5 2.01.71.4SPECIFICATIONSCover is optional*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.MODELPBW30F-5PBW30F-12PBW30F-15VOLTAGE[V]AC85 - 264 1f or DC110 -370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *8)CURRENT[A]FREQUENCY[Hz]50/60 (47 - 440) or DCINPUTACIN 100V 75typ (CURRENT1) 77typ (CURRENT1) 78typ (CURRENT1)EFFICIENCY[%]ACIN 200V 75typ (CURRENT1) 81typ (CURRENT1) 79typ (CURRENT1)ACIN 100V 15typ (CURRENT1) (At cold start)INRUSH CURRENT[A]ACIN 200V 30typ (CURRENT1) (At cold start)LEAKAGE CURRENT[mA]0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC62368-1,DENAN)VOLTAGE[V]t5/ ( +10V reference number )t12/ ( +24V reference number )t15/ ( +30V reference number )CURRENT1[A]1.5/ 1.51.3/ 1.31.0/ 1.0CURRENT2[A]*5 2.0/-1.7/-1.4/-LINE REGULATION[mV]*9*11 20max/ 36max60max/ 96max60max/ 96maxLOAD REGULATION 1[mV]*3*11 250max/ 100max600max/ 150max600max/ 150maxLOAD REGULATION RIPPLE[mVp-p]OUTPUT0to +50C *1 120max / 300max 150max / 300max 150max / 300maxRIPPLE NOISE[mVp-p]-10 -0C *1 160max / 360max 180max / 360max 180max / 360maxTEMPERATURE REGULATION[mV]DRIFT[mV]*2 20max48max60maxSTART-UP TIME[ms]200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]4.99 -6.00 (+V and -V are simultaneously adjusted)9.60 -13.2 (+V and -V are simultaneously adjusted)13.2 -16.5 (+V and -V are simultaneously adjusted)OUTPUT VOLTAGE SETTING[V]4.99 -5.30 (+V and -VCURRENT1)11.5 - 12.5 (+V and -V CURRENT1)14.4 - 15.6 (+V and -V CURRENT1)OVERCURRENT PROTECTIONWorks over 105% of rated current and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V] 6.90 -10.0 16.8 - 24.0 20.0 - 29.0CIRCUIT ANDOTHERS OPERATING INDICATION LED (Green)REMOTE ON/OFFNoneINPUT-OUTPUTAC3,000V 1minute, Cutoff current =10mA, DC500V 50MW min (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current =10mA, DC500V 50MW min (At Room Temperature)OUTPUT-FGAC500V 1minute, Cutoff current =25mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +71C (Refer to“Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxENVIRONMENTVIBRATION10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axisIMPACT196.1m/s2 (20G), 11ms, once each X, Y and Z axisSAFETY AND AGENCY APPROVALS (At only ACinput)UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATOR*12OTHERS*1 Measured by 20MHz oscilloscope or Ripple-Noisemeter(equivalent to KEISOKU-GIKEN : RM101).*2 Drift is the change in DC output for an eight hour periodafter a half-hour warm-up at 25C.*3 Figures for 0 to rated current 1.The current not measuredside is fixed.*4 Figures for 0 to rated current 2.The current not measuredPBA/PBW-28side is fixed.*5 The sum of +power -power must be less than output power.*6 t5,t12,t15 can be used as +10,+24 and +30.*7 When two or more units are used,they may not comply withthe harmonic attenuator. Please contact us for details.*8 Derating is required.*9 Figures to rated current 1.? 76 ?*10 Please contact us about safety approvals for the model withoption.*11 Please contact us about dynamic load and input response.*12 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.