Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
Small, Single phase input type: Screwless terminal (1-Stage filter)ESC/ESM/ESP seriesROrdering informationESC -10 -472 -O1 2 3 41 Series Name2 Rated Current3 Line to ground capacitor code:Refer to table 1.1.DIN rail installation type is optionElectric cable is not appended.table1.1 Line to ground capacitor codeCodeE E ES S S Leakage CurrentLinetogroundC M Pcapacitor(Input 125/250V 60Hz)(nominal value)000●●5A /10 A max Not Provided101●●12.5A /25 A max100pF221●●25A /50 A max220pF331●●37.5A /75 A max330pF471●●50A / 100 A max470pF681●●75.5A / 150 A max680pF102●●0.13 mA / 0.25mA max1,000pF222●●0.25 mA / 0.5 mA max2,200pF332●●0.38 mA / 0.75mA max3,300pF472●●0.5 mA / 1.0 mA max4,700pF*When the line to ground capacitor code isdifferent, the attenuation characteristic isdifferent.4 OptionD :DIN rail installation type* The dimensions change when the option is set.Refer to External view.Features of ESC/ESM/ESP series-Single Phase 250VAC (1-Stage filter)- Small EMI/EMC Filters that change input-output terminal and protection earth terminal of EA series intoscrewless terminal type-Torque management is unnecessary with screwlessESC : Attenuation type from 150kHz to 1MHz ESM : Low leakage current typeESP : Outside impulse attenuation typeSpecificationsESC-03-472ESC-06-472ESC-10-472ESC-16-472No.ItemsESM-03-000ESM-06-000ESM-10-000ESM-16-000ESP-03-472ESP-06-472ESP-10-472ESP-16-4721Rated Voltage[V]AC 1f 250 / DC2502Rated Current[A]3610163Test Voltage (Terminal-Mounting Plate)2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity4Isolation Resistance (Terminal-Mounting Plate)500 VDC 500MW min at room temperature and humidity5Leakage currentRefer to table 1.16DC resistance180mW max110mW max40mW max20mW max7Safety agency approval temperatures-25 to +85C (Refer to Derating Curve)8Operating temperature-40 to +85C (Refer to Derating Curve)9Operating humidity20 to 95%RH (Non condensing)10Storage temperature/humidity-40 to +85C/20 to 95%RH (Non condensing)11Vibration10 to 55Hz, 19.6m/s 2 (2G), 3min. Period, 1hour each X, Y and Z axis12Impact196.1m/s 2 (20G), 11ms Once each X, Y and Z axis13Safety agency approvalsUL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)14Case size (without projection) /Weight39X30X85 mm [1.54X1.18X3.35 inches] (WXHXD) /170g max (Option : -D refer to external view)Circuit DiagramDerating CurveCase1001CY3LINE2 CY4LOADLoad Factor [%]80604020EMI/EMCFilter0-40-30-204050 55 60 70 8090CY : Line to ground capacitor: Mounting PlateEA/ES-3 ? 778 ?Ambient Temperature [C]