title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
785/916

This page is the summary of page 785 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

ESC, ESM, ESP seriesInstruction Manual1 Applicable Electric Cable-Only use the electric cable that exists in the Table1.-Use the cable that conductor material is copper. Do not use thecable that conductor material is iron or aluminum. Never use theone other than the electric cable.Ex. Steel wire, Stick made of resin, other wire-Note that the current rating is different in each electric cable.-Strip so as not to damage the conductor at stripping sheath.-Strip specifi ed length of cable sheath (Refer to Table1).Strip Length can be confirmed with a gauge of the body case.Refer to External view.-Do not put solder on the conductor. It becomes impossible toconnect cable.Table.1 Applicable WireSolid wire Diameter 0.5mm to 1.2mm (AWG.22 to AWG.16)0.3mm 2 to 1.25mm 2 (AWG.22 to AWG.16)Stranded wireConductor diameter more than 0.18 mmSheath strip10mm to 12mmlength2 Applicable bar-type terminal3 State of crimped bar-type terminal? Bad conditionABCDABCDEFGHIJE F GCutComing offH I JThe wire protrudes from the sleeve.The conductor extremely protrudes from the point of the bar-typeterminal.The electric conductor is not inserted enough and the conductorhas been exposed from the terminal.The sheath strip length doesn’t suffi ce and the conductor is notenough inserted in the ferrules.Crimp is only the point of conductor.It crimps two electric cables.There is a damage or a disconnection part in the conductor.The point of the terminal is cut.It comes off the terminal when the cable is pulled.The sheath of the cable protrudes from the sleeve.4 Wiring Terminal Blocks(connecting/releasing)-The applicable bar-type terminal (Refer to Table 2) must be used,and after crimp, the size of bar-type terminal must be kept valueof Table 3. Use the applicable terminal (Refer to Table 2) andkeep the size of terminal , or you will not be able to connect cable.Contact us when the bar-type terminals other than the applicablebar-type terminal (Refer to Table 2) are used.-Connect cable so as not to conceal the button with the sleeveof the cable when a round terminals other than the applicableterminal are used.Table.2 Applicable bar-type terminalManufacturer Size model Crimp toolAWG.22 AI0.34-12TQAI0.5-10WHAWG.20AI0.5-12WHPhoenixContactNichifuFerrule(Crimp)BABarAWG.18AWG.16AWG.22-16Dia. CSleeveAI0.75-10GYAI0.75-12GYAI1-10RDAI1-12RDAI1.5-10BKAI1.5-12BKTGN TC-1.25-11TTGV TC-1.25-11TSleeve(Crimp)CRIMPFOXUD6-4NH11NH32NH65Table.3 Dimension of terminal at crimp[Dimensions in mm]Part DimensionA 1.1 to 2.6B 0.8 to 1.6Dia. C 0.8 to 1.6? 783 ?-One electric cable one insertion hole. When two or more is connected,it causes trouble.-Do connecting and releasing of the electric cable by using a flatbladedriver while pushing the connection/release button. Moreover,insert the conductor or the bar-type terminal to the end fully.-When you connect the stranded cable ,connect wires after lightlystranding wires.-Confi rm the electric cable is surely connected with the terminalafter connecting.- The check hole can be used for the check of wire connecting andinsulation and for the operation monitor etc.? Connecting : Stranded cable, Solid cable (Diameter 0.5 to 0.9)StepI Push the button with a fl at-blade driver.StepII Insert the cable into the hole while pushing the button.StepIII Release the flat-blade driver and cable connection iscompletion.StepI StepII StepIII121? Connecting : Solid wire (except diameter 0.5 to 0.9 ), bar type terminalInsert the cable into the insertion hole.*Insert it while pushing the button when it is not easy to insert it.? Releasing : Stranded wire, Solid wire, bar type terminalPull out the electric cable while pushing the button with flat-bladedriver.*Notice : Two insertion holes are released at the same time bypushing the button once. (Except PE terminal)-Use the fl at-blade driver that meets the size in Table 4.SideFrontTable.4 Dimension of flat-blade driver[Dimensions in mm]PartDimensionD1.0maxDEE3.0max212EA/ES-8EMI/EMCFilter