title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
794/916

This page is the summary of page 794 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

Single phase input type (1-stage filter)NAC/NAM/NAH/NAP series (40,50,60A)ROrdering informationNAC -50 -472 -O1 2 3 41 Series Name2 Rated Current3 Line to ground capacitor code:Refer to table 1.1 and table 1.2.4 OptionF:High input voltage (500VAC/600VDC)The terminal cover is retracted inside the unitDIN rail installation type is optiontable1.1Linetogroundcapacitorcode(Standard)N N N NA A A ALine to groundLeakage CurrentCode C M H Pcapacitor(Input 125/250V 60Hz)(nominalvalue)●●●0005A/10AmaxNotProvided●●●47150 A/ 100 A max 470pF222●●●0.25 mA/ 0.5 mA max 2,200pF472●●●0.5 mA/ 1.0 mA max 4,700pF223●●●1.25 mA/ 2.5 mA max 0.022 F683●●●1.75 mA/ 3.5 mA max 0.068 F224●6.0 mA/ 12.0 mA max 0.22 F155●27.5 mA/ 55.0 mA max 1.5 Ftable1.2Linetogroundcapacitorcode(Option:F)N N N NA A A ALine to groundLeakage CurrentCode C M H Pcapacitor(Input 250/500V 60Hz)(nominal value)103●●●0.5 mA/ 1.0 mA max 0.01 F223●●●1.0 mA/ 2.0 mA max 0.022 F683●●●2.5 mA/ 5.0 mA max 0.068 F* When the line to ground capacitor code isdifferent, the attenuation characteristic isdifferent.Features of NAC/NAM/NAH/NAP seriesEMI/EMCFilter- Single Phase 277VAC/300VDC (1-stage filter)This product is available 277VAC equipment in factory switchboards and building equipment- Withstand voltage 4,000 VAC (Line to ground capacitor code -000 to -472)NAC : High-attenuation type from 150kHz to 1MHzNAH : Ultra high-attenuation type from 9kHz to 1MHzSpecificationsNAM : Low leakage current typeNAP : Outside impulse high-attenuation typeNAC-40-472NAC-50-472NAC-60-472No.ItemsNAP-40-472NAP-50-472NAP-60-4721Rated Voltage2Rated Current[A]4050603Test Voltage (Terminal-Mounting Plate)4,000 VAC (Cutoff Current = 25mA), 1minute at room temperature and humidity *1 *24Isolation Resistance (Terminal-Mounting Plate)500 VDC 100MW min at room temperature and humidity *35Leakage currentRefer to table 1.1 and table 1.26DC resistance10mΩmax6.0mΩmax4.5mΩmax7Safety agency approval temperatures-25 to +85C (Refer to Derating Curve)8Operating temperature-40 to +85C (Refer to Derating Curve)9Operating humidity20 to 95%RH (Non condensing)10Storage temperature/humidity-40 to +85C/20 to 95%RH (Non condensing)11Vibration10 to 55Hz, 19.6m/s 2 (2G), 3min. Period, 1hour each X, Y and Z axis12Impact196.1m/s 2 (20G), 11ms Once each X, Y and Z axis13Safety agency approvalsUL60939 [Overvoltage Category :ⅢAltitude:3000m], CSA C22.2 No.8 (C-UL)EN60939 (DEMKO) [Overvoltage Category:ⅢAltitude:3000m] , ENEC14Case size (without projection) /Weight65×54×153mm [2.56×2.13×6.02 inches] (W×H×D) / 750g max*1 "NAO-OO-OOO-F" : 2,500 VAC (Cutoff Current = 100mA) , 1 minute at room temperature and humidity.*2 Capacitor code“223”,“683”,“224”and“155”of "NAO-OO-OOO" : 2,800VDC (Cutoff Current = 10mA) , 1 minute at room temperature and humidity.*3 Capacitor code“224”and“155”: isolation resistance specification is deleted.NA-9? 792 ?