Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
RPBA/PBWAC-DC Power Supplies Enclosed TypePBW50FOrdering informationPB W 50 F -O -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.Cover is optional*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.1 Series name2 Dual output3 Output wattage4 Universal input5 Output voltage6 Optional *9C : with CoatingG : Low leakage current(0.15mA max / ACIN 240V)E : Low leakage currentand EMI class A(0.5mA max / ACIN 240V)T : Vertical terminal blockJ1 : VH (J.S.T.) connector typeR : with Remote ON/OFFN : with CoverN1 : with DIN railV : Output voltage settingpotentiometer externallyMODELPBW50F-5PBW50F-12PBW50F-15MAX OUTPUT WATTAGE[W]*6 3050.451VOLTAGE[V] *8 t5 ( +10 )t12 ( +24 )t15 ( +30 )DC OUTPUTCURRENT1[A]3.02.11.7CURRENT2[A]*6 4.02.72.4SPECIFICATIONSMODELPBW50F-5PBW50F-12PBW50F-15VOLTAGE[V]AC85 - 264 1f or DC120 -370 (AC50 or DC70 Please refer to the instruction manual 1.1 Input voltage *3)CURRENT[A]FREQUENCY[Hz]50/60 (47 -63)ACIN 100V 76typ (CURRENT1) 81typ (CURRENT1) 81typ (CURRENT1)EFFICIENCY[%]INPUTACIN 200V 77typ (CURRENT1) 83typ (CURRENT1) 83typ (CURRENT1)POWER FACTOR(Io=100%)ACIN 100V 15typ (CURRENT1) (At cold start)INRUSH CURRENT[A]ACIN 200V 30typ (CURRENT1) (At cold start)LEAKAGE CURRENT[mA]0.40/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC62368-1,DENAN)VOLTAGE[V]t5/ ( +10V reference number )t12/ ( +24V reference number )t15/ ( +30V reference number )CURRENT1[A]3.0/ 3.02.1/ 2.11.7/ 1.7CURRENT2[A]*6 4.0/-2.7/-2.4/-LINE REGULATION[mV]20max/ 36max48max/ 96max60max/ 96maxLOAD REGULATION 1[mV]*4 250max/ 100max600max/ 150max600max/ 150maxLOAD REGULATION 2[mV]*5 500max/-750max/-750max/-RIPPLE[mVp-p]OUTPUT0to +50C *1 120max / 300max 150max / 300max 150max / 300maxRIPPLE NOISE[mVp-p]-10 -0C *1 160max / 360max 180max / 360max 180max / 360maxTEMPERATURE REGULATION[mV]DRIFT[mV]*2 20max48max60maxSTART-UP TIME[ms]350typ(ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]4.99 -6.00 (+V and -V are simultaneously adjusted)9.60 -13.2 (+V and -V are simultaneously adjusted)13.2 -16.5 (+V and -V are simultaneously adjusted)OUTPUT VOLTAGE SETTING[V]4.99 -5.30 (+V and -VCURRENT1)11.5 - 12.5 (+V and -V CURRENT1)14.4 - 15.6 (+V and -V CURRENT1)OVERCURRENT PROTECTIONWorks over 105% of rated current and recovers automaticallyPROTECTION OVERVOLTAGE PROTECTION[V] 6.90 -10.0 16.8 - 24.0 20.0 - 29.0CIRCUIT ANDOTHERS OPERATING INDICATION LED (Green)REMOTE ON/OFFOptional (Required external power source)INPUT-OUTPUT-RC*7 AC3,000V 1minute, Cutoff current =10mA, DC500V 50MW min (At Room Temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current =10mA, DC500V 50MW min (At Room Temperature)OUTPUT-RC-FG*7 AC500V 1minute, Cutoff current =100mA, DC500V 50MW min (At Room Temperature)OPERATING TEMP.,HUMID.AND ALTITUDE-10 to +71C (Refer to“Derating”), 20 - 90%RH (Non condensing) 3,000m (10,000feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) maxENVIRONMENTVIBRATION10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Yand Z axisIMPACT196.1m/s2 (20G), 11ms, once each X, Y and Z axisSAFETY AND AGENCY APPROVALS (At only ACinput)UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATORComplies with IEC61000-3-2*10OTHERS*1 Measured by 20MHz oscilloscope or Ripple-Noisemeter(equivalent to KEISOKU-GIKEN : RM101).*2 Drift is the change in DC output for an eight hour periodafter a half-hour warm-up at 25C.*3 Derating is required.*4 Figures for 0 to rated current 1.The current not measuredside is fixed.PBA/PBW-30*5 Figures for 0 to rated current 2.The current not measuredside is fixed.*6 The sum of +power -power must be less than output power.*7 RC is applied to remote ON/OFF option. RC is isolated withinput/output and FG.*8 t5,t12,t15 can be used as +10,+24 and +30.? 78 ?*9 Please contact us about safety approvals for the model withoption.*10 Please contact us about class C.* Parallel operation with other model is not possible.* Derating is required when operated with cover.* A sound may occur from power supply at peak loading.