COSEL Power Supply, Noise Filter 2025 Product Catalog

RThree phase input type(1-stage filter)JAC series(6-30A)The terminal cover is retracted inside the unitFeatures of JAC seriesOrdering informationJAC -30 -683 -O1 2 3 4DIN rail installation type is option1 Model Name2 Rated Current3 Line to ground capacitor code:See table 1.1.table1.1 Line to ground capacitor codeLeakage Current Line to groundCode (Input 250/500V 60Hz) capacitor(Only“224”is 250/400V 60Hz) (nominal value)103 0.5mA / 1.0mA max 10,000pF223 1.0mA / 2.0mA max 22,000pF683 2.5mA / 5.0mA max 68,000pF224 15mA / 24mA max 220,000pF*When the line to ground capacitor code isdifferent, the attenuation characteristic isdifferent.4 OptionD:DIN rail installation type* The dimensions change when the option is set.Refer to External view.H:Ultra high-attenuation type“103”,“223”,“683”is applied.U:Improve differential mode attenuation(Rated voltage 250V)Compact and low profile, common mode EMI/EMC filters in 150kHz to 1MHz (1-stage filter)- Three Phase 500 VAC - Push down type terminal block- Selectable leakage current value, Ultra high-attenuation type“224”for EU (Y type with neutral earth system)SpecificationsNo.ItemsJAC-06-683JAC-10-683JAC-20-683JAC-30-6831Rated Voltage[V]AC Three Phase 500 (voltage range:528 max) 50/60Hz *1 *22Rated Current[A]61020303Test Voltage (Terminal-Mounting Plate)2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity *34Isolation Resistance (Terminal-Mounting Plate)500 VDC 100MW min at room temperature and humidity *45Leakage current 250/500V 60Hz2.5mA/5.0mA max6DC resistance100mW max45mW max15mW max8mW max7Safety agency approval temperatures-25 to +85C (Refer to Derating Curve)8Operating temperature-40 to +85C (Refer to Derating Curve)9Operating humidity20 to 95%RH (Non condensing)10Storage temperature/humidity-40 to +85C/20 to 95%RH (Non condensing)11Vibration10 to 55Hz, 19.6m/s 2 (2G), 3min. Period, 1hour each X, Y and Z axis12Impact196.1m/s 2 (20G), 11ms Once each X, Y and Z axis13Safety agency approvalsUL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC14Case size (without projection)63X44X132 mm (WXHXD) (Option: -D refer to external view)[2.48X1.73X5.20 inches] (WXHXD)15Weight440g max*1 Capacitor code“224”: Three Phase D-connection 400 (440 max), Y-connection 500 (528 max).*2“JAC-OO-OOO-U”: Three Phase 250 (275 max).*3 Capacitor code“224”: 2,800VDC (Cutoff Current = 10mA), 1 minute at room temperature and humidity.*4 Capacitor code“224”: Isolation resistance specification is deleted.Circuit Diagram(1) Line to ground capacitor code : 103, 223, 683(2) Line to ground capacitor code : 224LINE LINECase CaseLOAD LOAD LINE LINECase CaseLOAD LOADLINE 1 LINE 1CaseCaseLOAD 4 LOAD 4 LINE 1 LINE 1CaseCaseLOAD 4 LOAD 42132321323 CX CX CX545421656532CX CXCXCXCXCXCX6632154543265653CXCX CXCX CXCXCXCX CXCX CXCX 66CXCX CXCX CXCXCXCXCXCYCXCYCXCX CXCX CXCXCXCX CXCX CXCYCXCYCYCYCYCYCYCYCX : CX Line : to Line line to CY capacitor line CY capacitorCY : CY Line : to Line ground to ground capacitor capacitorCX : CX Line : to Line line to capacitor line capacitorCY : CY Line : to Line ground to ground capacitor capacitorCX : CX Line Mounting : to Line Mounting line to Plate capacitor line Plate capacitorCX : CX Line Mounting : to Line Mounting line to Plate capacitor line Plate capacitorCY : CY Line : to Line ground to ground capacitor capacitorCY : CY Line : to Line ground to ground capacitor capacitor(3) Line to ground capacitor code : Mounting :: Mounting 103, Plate 223, Plate 683 (4) Line to ground capacitor : Mounting code : Mounting : 224PlateLINECase CaseLOAD LINECase CaseOption LINE: ULOAD Option LINE : ULOAD LOADLINE 1 LINE 1CaseCaseLOAD 4 LOAD 4 LINE 1 LINE 1CaseCaseLOAD 4 LOAD 42121545421215454323265653232656533CXCX CXCX CXCXCXCXCXCX6633CXCX CXCX CXCXCXCX CXCX CXCX 66Load Factor [%]Derating Curve1008070604020100-40 -30-20 40 50 60Ambient Temperature [ ]70 80 90EMI/EMCFilterCXCX CXCX CXCXCXCXCXCYCXCYCXCX CXCYCYCYCYCX : CX Line : to Line line to capacitor line CY capacitor CYCY : CY Line : to Line ground to ground capacitor capacitorCX : CX Line Mounting : to Line Mounting line to Plate capacitor line Plate capacitorCY : CY Line : to Line ground to ground capacitor capacitor: Mounting : Mounting Plate PlateCX CX CX CX CX CX CX CX CXCY CYCY CYCX : CX Line : to Line line to capacitor line capacitorCY : CY Line : to Line ground to ground capacitor capacitorCX : CX Line Mounting : to Line Mounting line to Plate capacitor line Plate capacitorCY : CY Line : to Line ground to ground capacitor capacitor: Mounting : Mounting Plate PlateJAC-1 ? 804 ?