title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
812/916

This page is the summary of page 812 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

Three phase input type(1-stage filter)JAC series(40,50,60A)ROrdering informationJAC -50 -683 -O1 2 3 4Features of JAC seriesCompact and low profile, common mode EMI/EMC filters in150kHz to 1MHz (1-stage filter)- Three phase rated voltage 500 VAC (voltage range : 528V max)- Selectable leakage current value, Ultra high-attenuation type“224”,“155”for EU (Y type with neutral earth system)Specifications1Series Name2 Rated Current3 Line to ground capacitor code:See table 1.1.table1.1 Line to ground capacitor codeCode103223683224155Leakage Current *1Upper row : D-connectionLower row : Y-connection0.5mA / 1.0mA max0.05mA / 0.1mA max1.0mA / 2.0mA max0.1mA / 0.2mA max2.5mA / 5.0mA max0.35mA / 0.7mA max15mA / 24mA max2.0mA / 4.0mA max80mA / 125mA max9.0mA / 18mA maxLine to groundcapacitor(nominal value)0.01μF0.022μF0.068μF0.22μF1.5μF* When the line to ground capacitor code is different,the attenuation characteristic is different.*1 Input 250/500V 60Hz(D-connection of“224”,“155”is 250/400V 60Hz)4 OptionH:Ultra high-attenuation type“103”,“223”,“683”is applied.U:Improve differential mode attenuation(Rated voltage 250V)No.ItemsJAC-40-683JAC-50-683JAC-60-6831Rated Voltage[V]AC Three Phase 500 (voltage range:528 max) 50/60Hz *2 *32Rated Current[A]4050603Test Voltage (Terminal-Mounting Plate)2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity *44Isolation Resistance (Terminal-Mounting Plate)500 VDC 100MW min at room temperature and humidity *55Leakage current 250/500V 60Hz2.5mA/5.0mA max6DC resistance7.0mW max5.0mW max3.5mW max7Safety agency approval temperatures-40 to +85C (Refer to Derating Curve)8Operating temperature-40 to +85C (Refer to Derating Curve)9Operating humidity20 to 95%RH (Non condensing)10Storage temperature/humidity-40 to +85C/20 to 95%RH (Non condensing)11Vibration10 to 55Hz, 19.6m/s 2 (2G), 3min. Period, 1hour each X, Y and Z axis12Impact196.1m/s 2 (20G), 11ms Once each X, Y and Z axis13Safety agency approvalsUL60939[Overvoltage Category :ⅢAltitude : 3000m], CSA C22.2 No.8 (C-UL)EN60939(DEMKO)[Overvoltage Category:ⅢAltitude:3000m] , ENEC14Case size (without projection)65X54X153 mm (WXHXD)[2.56X2.13X6.02 inches] (WXHXD)15Weight800g max*2 Capacitor code“224”and“155”: Three Phase D-connection 400 (440 max), Y-connection 500 (528 max).*3“JAC-OO-OOO-U”: Three Phase 250 (275 max).*4 Capacitor code“224”and“155”: 2,800VDC (Cutoff Current = 10mA), 1 minute at room temperature and humidity.*5 Capacitor code“224”and“155”: Isolation resistance specification is deleted.Circuit Diagram(1) Line to ground capacitor code : 103, 223, 683(2) Line to ground capacitor code : 224, 155LINECaseLOAD LINECaseLOADLINECaseLOAD LINECaseLOAD141412451245235623563636CYCYCYCYCYCY : Line to ground capacitorCY : Line to ground capacitorCY : Line Mounting to ground Plate capacitorCY : Line Mounting to ground Plate capacitor: Mounting Plate(3) Line to ground capacitor code : 103, 223, 683: Mounting Plate(4) Line to ground capacitor code : 224, 155Option : UCaseOption Case : ULINELOAD LINELOADLINECaseLOAD LINECaseLOAD141412451245235623563636Load Factor [%]Derating Curve1008070604020100-40 -30-20 40 50 60Ambient Temperature [ ]*Keep free ventilation holes for cooling.70 80 90EMI/EMCFilterCYCYCYCY : Line to ground capacitorCY : Line Mounting to ground Plate capacitor: Mounting PlateCYCYCY : Line to ground capacitorCY : Line Mounting to ground Plate capacitor: Mounting PlateJAC-7 ? 810 ?