title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
84/916

This page is the summary of page 84 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

PBA/PBWDeratingPBA?PBW-series? PBA10F, PBA15F, PBW15F, PBA30F, PBW30FInput voltage Derating Curve? PBA1500F Input voltage Derating CurveLoad[%]10080Load[%]10080at AC100V85 90[AC V]85 95[AC V]? PBA10F, PBA15F, PBW15F, PBA30F, PBW30F, PBA50F, PBW50F, PBA75F, PBA100F,PBA150F Ambient temperature derating curveABCLoad factor [%]100806040200-100101Convection2Forced air (0.5m 3 / min)2030 [20] 40 [30] 50 [40] 60 [50] 70 [60] 80 [70]20 [10] 30 [20] 40 [30] 50 [40] 60 [50] 70 [60]20 [10] 30 [20] 40 [30] 50 [40] 60 [50] 70 [60]Ambient temperature [C] Inside [ ]is with case cover12!In the hatched area, the specifi cation of Ripple, Ripple Noise is different from other area.! The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be infl uenced by the heat from thepower supply. Please consult us for more details.!Make sure the temperature at point A is less than the temperatures shown in Instruction Manual 4.? PBA300F, PBA600F, PBA1000F, PBA1500F, PBA1500T Ambient temperature derating curveLoad factor[%]1009080706050403020100-20-100102030405060Ambient temperature[C]7071C80!In the hatched area, the specification of Ripple, Ripple Noise is different from other area.!Derating curve depending on an ambient temperature (temperature of air sucked in for a cooling purpose) is shown above.PBA/PBW-34? 82 ?