title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
840/916

This page is the summary of page 840 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

Three phase input type(1-stage filter)FTA series(40,50,60A)RFeatures of FTA seriesCircuit DiagramOrdering informationFTA -50 -683 -O1 2 3 4Book type (Space-saving type)- 1-stage filter General-purpose High-attenuation (150kHz - 1MHz)- Selectable leakage current value, Ultra high attenuation type "335" forEU(Wye type with neutral earth system), With switch of line to groundcapacitor "-G"Specifications1 Model Name2 Rated Current3 Line to ground capacitor code:See table 1.1.table1.1 Line to ground capacitor codeCodeLeakage Current(Input 250/500V 60Hz)(335only 250/400V 60Hz)Line to groundcapacitor(nominal value)223 1.0mA/2.0mA max 22,000pF683 2.5mA/5.0mA max 68,000pF104 3.5mA/7.0mA max 100,000pF335 160mA/250mA max 3.3 F*When the line to ground capacitor code isdifferent, the attenuation characteristic isdifferent.4 OptionH:Ultra high attenuation type"335" is not applied.U:Improve differential mode attenuation(Rated voltage 250V)G:With switch of line to ground capacitorOnly "335" is applied.*Leakage current 160mA/250mA max whenthe switch state is ON (switched to“”).10μA/16μA max when the switch state is OFF(switched to“”).No.ItemsFTA-40-683FTA-50-683FTA-60-6831Rated Voltage[V]AC Three Phase 500 (voltage range:528 max) 50/60Hz *1 *22Rated Current[A]4050603Test Voltage (Terminal-Mounting Plate)2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity *34Isolation Resistance (Terminal-Mounting Plate)500 VDC 100MW min at room temperature and humidity *45Leakage current 250/500V 60Hz2.5mA/5.0mA max6DC resistance8.5mW max6mW max4.5mW max7Safety agency approval temperatures-25 to +85C (Refer to Derating Curve)8Operating temperature-40 to +85C (Refer to Derating Curve)9Operating humidity20 to 95%RH (Non condensing)10Storage temperature/humidity-40 to +85C/20 to 95%RH (Non condensing)11Vibration10 to 55Hz, 19.6m/s 2 (2G), 3min. Period, 1hour each X, Y and Z axis12Impact196.1m/s 2 (20G), 11ms Once each X, Y and Z axis13Safety agency approvalsUL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC14Case size (without projection)65X84X153 mm (WXHXD) (Option: -G refer to external view)[2.56X3.31X6.02 inches] (WXHXD)15Weight1.2kg max*1 Only capacitor code“335”, Three Phase D-connection : 400 (440 max), Wye-connection : 500 (528 max)*2 Only“FTA-O O-O O O-U”, Three Phase 250 (275 max)*3 Only capacitor code“335”, 2,800VDC (Cutoff Current = 10mA), 1minute at room temperature and humidity.*4 Only capacitor code“335”, Isolation resistance specification is deleted.(1) Line to ground capacitor code : 223, 683, 104(2) Line to ground capacitor code : 335(3) Line to ground capacitor code : 223, 683, 104Option : ULINECaseLOADLINECaseLOADLINECaseLOAD124512451245363636CYCYCYCYCYEMI/EMCFilterLINE123CaseCY : Line to ground capacitor: Mounting PlateCYCY : Line to ground capacitor: Mounting PlateLOAD456LINE123CaseCY : Line to ground capacitor: Mounting Plate(4) FTA-O O-335-U (5) FTA-O O-335-GDerating CurveSWSW : SwitchCY : Line to ground capacitor(The switch state is OFF): Mounting PlateCYLOAD456Load Factor [%]100806040200-40 -30CY : Line to ground capacitor: Mounting Plate-20 40 50 60 70 80 90Ambient Temperature [C]FTA-1 ? 838 ?