Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
Three phase input type(1-stage filter)FTA series(80,100,125,150A)Ordering informationFTA -80 -683 -O1 2 3 4RFeatures of FTA seriesBook type (Space-saving type)- 1-stage filter General-purpose High-attenuation (150kHz - 1MHz)- Selectable leakage current value, Ultra high attenuation type"155","335" for EU(Wye type with neutral earth system), With switch of line to ground capacitor "-G"SpecificationsCircuit Diagram1 Model Name2 Rated Current3 Line to ground capacitor code:See table 1.1.table1.1 Line to ground capacitor codeCodeLeakage Current(Input 250/500V 60Hz)(155,335only 250/400V 60Hz)Line to groundcapacitor(nominal value)223 1.0mA/2.0mA max 22,000pF683 2.5mA/5.0mA max 68,000pF104 3.5mA/7.0mA max 100,000pF155 160mA/250mA max 1.5 F335 320mA/500mA max 3.3 F*When the line to ground capacitor code isdifferent, the attenuation characteristic is different.4 OptionH:Ultra high attenuation type"155","335" is not applied.S:Hexagon socket head cap screw(Standard type is Hexagon head screw)U:Improve differential mode attenuation(Rated voltage 250V)G:With switch of line to ground capacitorOnly "155","335" is applied.*"155" is Leakage current 160mA/250mA maxwhen the switch state is ON (switched to“”).50μA/80μA max when the switch state is OFF(switched to“”)."335" is Leakage current 320mA/500mA maxwhen the switch state is ON (switched to“”).50μA/80μA max when the switch state is OFF(switched to“”).No.ItemsFTA-80-683FTA-100-683FTA-125-683FTA-150-6831Rated Voltage[V]AC Three phase 500 (voltage range:528 max) 50/60Hz *1 *22Rated Current[A]801001251503Test Voltage (Terminal-Mounting Plate)2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity *34Isolation Resistance (Terminal-Mounting Plate)500 VDC 100MW min at room temperature and humidity *45Leakage current 250/500V 60Hz2.5mA/5.0mA max6DC resistance5mW max4mW max3mW max3mW max7Safety agency approval temperatures-25 to +85C (Refer to Derating Curve)8Operating temperature-40 to +85C (Refer to Derating Curve)9Operating humidity20 to 95%RH (Non condensing)10Storage temperature/humidity-40 to +85C/20 to 95%RH (Non condensing)11Vibration10 to 55Hz, 19.6m/s 2 (2G), 3min. Period, 1hour each X, Y and Z axis12Impact196.1m/s 2 (20G), 11ms Once each X, Y and Z axis13Safety agency approvalsUL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC14 Case size (without projection)100X130X210 mm (WXHXD)(Option: -G refer to external view)[3.94X5.12X8.27 inches]15 Weight 3.1kg max 4.2kg max*1 Only capacitor code and option“155”,“335”, Three Phase D-connection:400 (440 max), Wye-connection:500(528 max)*2 Only option“U”, Three Phase 250(275 max)*3 Only capacitor code and option“155”,“335”, 2,800VDC (Cutoff Current = 10mA), 1minute at room temperature and humidity.*4 Only capacitor code and option“155”,“335”, Isolation resistance specification is deleted.100X170X260 mm(WXHXD)(Option: -G refer to external view)[3.94X6.69X10.24 inches](1) Line to ground capacitor code : 223, 683, 104(2) Line to ground capacitor code : 155, 335(3) Line to ground capacitor code : 223, 683, 104Option : ULINECaseLOADLINECaseLOADLINECaseLOAD124512451245363636CYCYCYCYCYCYEMI/EMCFilterCY : Line to ground capacitor: Mounting Plate(4) Line to ground capacitor code : 155, 335Option : ULINECaseLOAD142536CY CYCY : Line to ground capacitor: Mounting PlateCY : Line to ground capacitor: Mounting Plate(5) Line to ground capacitor code : 155, 335Option : GLINECaseLOAD142536SWCY CYSW : SwitchCY : Line to ground capacitor(The switch state is OFF): Mounting PlateFTA-7 ? 844 ?Derating CurveLoad Factor [%]10080604020CY : Line to ground capacitor: Mounting Plate0-40-30-20405060708090Ambient Temperature [C]*Keep free ventilation holes for cooling.