Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
Three-phase input type(2-stage filter)YAC series(120,160,200,300A)ROrdering informationYAC -120 -6851 2 31 Series Name2 Rated Current3 Line to Ground Capacitor Code:See Table 1.1.Table 1.1 Line to Ground Capacitor CodeCodeLeakage CurrentY-ConnectionLine to GroundCapacitor(nominal Value)CY1 CY210.7mA typ *26856.8μF Not provided55mA max *341.5mA typ *2226 *1 1.5μF 6.8μF×3220mA max *3*1“226”is applied only to“300A”type.*2 At normal operation (Input 500V 50Hz) withapplying 10V in between N (N') and FG(According to IEC60939).*3 At the worst case under normal operation(Input 500V 60Hz).Features of YAC series- Three-Phase Four-Wire System EMI/EMC Filter ideal for High-power office equipment and Energy storage systems- Suitable for 150kHz-1MHz conduction noise reduction- Product lineup that can flexibly respond to system and capacity changes in a compact/same body sizeSpecificationsNo.ItemsYAC-120-685YAC-160-685YAC-200-685YAC-300-6851Rated Voltage[VAC]Three-Phase Four-Wire System Y-Connection 500/289 (Voltage Range:528/305 max) 50/60Hz *42Rated Current[A]1201602003003Test Voltage (Terminal-Mounting Plate)2,800 VDC (Cutoff Current = 10mA), 1minute at room temperature and humidity4Isolation Resistance (Terminal-Mounting Plate)500 VDC 5MW min. at room temperature and humidity *55Leakage CurrentRefer to table 1.16DC Resistance4.5mW max3.0mW max2.5mW max1.5mW max7Operating Temperature/Humidity-40 to +85C (Refer to Derating Curve)/20 to 95%RH (Non condensing)8Storage Temperature/Humidity-40 to +85C/20 to 95%RH (Non condensing)9Vibration10 to 55Hz, 19.6m/s 2 (2G), 3min. Period, 1hour each X, Y and Z axis10Impact196.1m/s 2 (20G), 11ms Once each X, Y and Z axis11Safety Agency ApprovalsUL60939〔Overvoltage Category:ⅢAltitude:3000m〕, CSA C22. 2 No. 8(C-UL)EN60939(DEMKO)〔Overvoltage Category:ⅢAltitude:3000m〕, ENEC12Case Size (Without Projection)157×140×340mm(W×H×D)[6.18×5.51×13.39 inches](W×H×D)13Weight9.0kg max5.5kg max*4 Voltage indicates“Line Voltage/Phase Voltage”.*5 Only“YAC-300-226”, Isolation Resistance specification is deleted.Circuit Diagram(1)Line to Ground Capacitor Code : 685CaseDerating Curve100LINE123NCY1CY145LOAD6N'Load Factor [%]8070604020100-40 -30CY1 : Line to Ground Capacitor : Mounting Plate(2)Line to Ground Capacitor Code : 226Case-20 40 50 60Ambient Temperature [C]70 80 85 90LINE123N45LOAD6N'EMI/EMCFilterCY1CY1CY1CY1CY1CY1CY1CY1CY2CY2CY1,CY2 : Line to Ground Capacitor: Mounting PlateYAC-3? 854 ?