title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
856/916

This page is the summary of page 856 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

Three-phase input type(2-stage filter)YAC series(120,160,200,300A)ROrdering informationYAC -120 -6851 2 31 Series Name2 Rated Current3 Line to Ground Capacitor Code:See Table 1.1.Table 1.1 Line to Ground Capacitor CodeCodeLeakage CurrentY-ConnectionLine to GroundCapacitor(nominal Value)CY1 CY210.7mA typ *26856.8μF Not provided55mA max *341.5mA typ *2226 *1 1.5μF 6.8μF×3220mA max *3*1“226”is applied only to“300A”type.*2 At normal operation (Input 500V 50Hz) withapplying 10V in between N (N') and FG(According to IEC60939).*3 At the worst case under normal operation(Input 500V 60Hz).Features of YAC series- Three-Phase Four-Wire System EMI/EMC Filter ideal for High-power office equipment and Energy storage systems- Suitable for 150kHz-1MHz conduction noise reduction- Product lineup that can flexibly respond to system and capacity changes in a compact/same body sizeSpecificationsNo.ItemsYAC-120-685YAC-160-685YAC-200-685YAC-300-6851Rated Voltage[VAC]Three-Phase Four-Wire System Y-Connection 500/289 (Voltage Range:528/305 max) 50/60Hz *42Rated Current[A]1201602003003Test Voltage (Terminal-Mounting Plate)2,800 VDC (Cutoff Current = 10mA), 1minute at room temperature and humidity4Isolation Resistance (Terminal-Mounting Plate)500 VDC 5MW min. at room temperature and humidity *55Leakage CurrentRefer to table 1.16DC Resistance4.5mW max3.0mW max2.5mW max1.5mW max7Operating Temperature/Humidity-40 to +85C (Refer to Derating Curve)/20 to 95%RH (Non condensing)8Storage Temperature/Humidity-40 to +85C/20 to 95%RH (Non condensing)9Vibration10 to 55Hz, 19.6m/s 2 (2G), 3min. Period, 1hour each X, Y and Z axis10Impact196.1m/s 2 (20G), 11ms Once each X, Y and Z axis11Safety Agency ApprovalsUL60939〔Overvoltage Category:ⅢAltitude:3000m〕, CSA C22. 2 No. 8(C-UL)EN60939(DEMKO)〔Overvoltage Category:ⅢAltitude:3000m〕, ENEC12Case Size (Without Projection)157×140×340mm(W×H×D)[6.18×5.51×13.39 inches](W×H×D)13Weight9.0kg max5.5kg max*4 Voltage indicates“Line Voltage/Phase Voltage”.*5 Only“YAC-300-226”, Isolation Resistance specification is deleted.Circuit Diagram(1)Line to Ground Capacitor Code : 685CaseDerating Curve100LINE123NCY1CY145LOAD6N'Load Factor [%]8070604020100-40 -30CY1 : Line to Ground Capacitor : Mounting Plate(2)Line to Ground Capacitor Code : 226Case-20 40 50 60Ambient Temperature [C]70 80 85 90LINE123N45LOAD6N'EMI/EMCFilterCY1CY1CY1CY1CY1CY1CY1CY1CY2CY2CY1,CY2 : Line to Ground Capacitor: Mounting PlateYAC-3? 854 ?