title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
868/916

This page is the summary of page 868 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

Three phase input type(2-stage filter)FTB series(80,100,150A)ROrdering informationFTB -80 -663 -O1 2 3 41 Model Name2 Rated Current3 Line to ground capacitor code:See table 1.1.table1.1 Line to ground capacitor codeFeatures of FTB seriesBook type (Space-saving type)- 2-stage filter High-attenuation (150kHz - 1MHz)- Selectable leakage current value,Ultra high-attenuation type"-355-L" for EU (Y type with neutral earth system)CodeLeakage Current *2Upper row : D-connectionLower row : Y-connectionLine to groundLine to groundcapacitor CY1capacitor CY2(nominal value)(nominal value)1.0mA/2.0mA max20310,000pF 10,000pF0.1mA/0.2mA max2.5mA/5.0mA max66333,000pF 33,000pF0.35mA/0.7mA max12mA/24mA max324220,000pF 100,000pF1.5mA/3.0mA max330mA/515mA max355 *1220,000pF 3,300,000pF40mA/80mA max*When the line to ground capacitor code is different, theattenuation characteristic is different.*1“355”is applied only to“L”type.*2 Input 250/500V 60Hz(Only D-connection of“355”is 250/400V 60Hz)4 OptionH:Ultra high-attenuation type“355”is not appliedS:Hexagon socket head cap screw(Standard type is Hexagon head screw)L:Ultra high-attenuation type for EUSpecificationsNo.ItemsFTB-80-663FTB-100-663FTB-150-6631Rated Voltage[V]AC Three Phase 500 (voltage range:528 max) 50/60Hz *32Rated Current[A]801001503Test Voltage (Terminal-Mounting Plate)2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity *44Isolation Resistance (Terminal-Mounting Plate)500 VDC 100MW min at room temperature and humidity *55Leakage current 250/500V 60Hz2.5mA/5.0mA max6DC resistance10mW max8mW max6mW max7Safety agency approval temperatures-25 to +85C (Refer to Derating Curve)8Operating temperature-40 to +85C (Refer to Derating Curve)9Operating humidity20 to 95%RH (Non condensing)10Storage temperature/humidity-40 to +85C/20 to 95%RH (Non condensing)11Vibration10 to 55Hz, 19.6m/s 2 (2G), 3min. Period, 1hour each X, Y and Z axis12Impact196.1m/s 2 (20G), 11ms Once each X, Y and Z axis13Safety agency approvalsUL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC14Case size (without projection)15Weight5.3kg max7.8kg max*3 Only capacitor code“355”, Three Phase D-connection : 400 (440 max), Y-connection : 500 (528 max)*4 Only capacitor code“324”,”355”2,800 VDC (Cutoff Current = 10mA), 1minute at room temperature and humidity.*5 Only capacitor code“355”, Isolation resistance specification is deleted.Circuit Diagram(1) Line to ground capacitor code : 203, 663, 324CaseLINELOADDerating Curve100123CY1CY1CY2CY2456Load Factor [%]80604020(2) FTB-O O-355-LLINECaseCY1, CY2 : Line to ground capacitor: Mounting PlateLOAD0-40 -30-20 40 50 60 70 80 90Ambient Temperature [C]123456*Keep free ventilation holes for cooling.EMI/EMCFilterCY1CY1CY2 CY2CY1, CY2 : Line to ground capacitor: Mounting PlateFTB-1 ? 866 ?