Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
PJARAC-DC Power Supplies Enclosed TypePJA100FOrdering informationPJ A 100 F -O -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-04-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6C : with CoatingR : Remote on/off(Required externalpower source)J : EP (Tyco Electronics)connector typeJ1 : VH (J.S.T.)connector typeT : Vertical terminal blockN2 : with DIN railSee 6.1 in Instruction Manual.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.SPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERSISOLATIONENVIRONMENTSAFETY ANDNOISEREGULATIONS* Please consider "PBA100F-5-N" about 5V output with case cover.MODELPJA100F-12PJA100F-15PJA100F-24PJA100F-36PJA100F-48VOLTAGE[V]AC85 - 264 1f (Output derating is required at AC85V - 115V. Refer to“Derating”and instruction manual 1.1, 3)ACIN 100V1.2typ (Io=90%)CURRENT[A]ACIN 115V1.1typ (Io=100%)ACIN 230V0.6typ (Io=100%)FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 100V82typ (Io=90%)83typ (Io=90%)85typ (Io=90%)86typ (Io=90%)86typ (Io=90%)EFFICIENCY[%]ACIN 115V82typ (Io=100%)83typ (Io=100%)85typ (Io=100%)86typ (Io=100%)86typ (Io=100%)ACIN 230V85typ (Io=100%)86typ (Io=100%)88typ (Io=100%)89typ (Io=100%)89typ (Io=100%)ACIN 100V0.98typ (Io=90%)POWER FACTORACIN 115V0.98typ (Io=100%)ACIN 230V0.90typ (Io=100%) * Power factor correction is stopped at AC250V or more.ACIN 100V16typ (Io=90%) Ta=25C at cold startINRUSH CURRENT[A]ACIN 115V16typ (Io=100%) Ta=25C at cold startACIN 230V32typ (Io=100%) Ta=25C at cold startLEAKAGE CURRENT[mA]0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]1215243648CURRENT[A]ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to“Derating”)ACIN 115V-264V 8.4 6.7 4.3 2.8 2.1WATTAGE[W]ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to“Derating”)ACIN 115V-264V 100.8 100.5 103.2 100.8 100.8LINE REGULATION[mV]*348max60max96max144max192maxLOAD REGULATION[mV] *3RIPPLE[mVp-p]*1Io: load factorRIPPLE NOISE[mVp-p]*1Io: load factorIo=30 to 100% 100max 120max 150max 150max 300maxIo=0 to 30% Burst operation (Please contact us about detail)0 to +40C120max120max120max150max150max-10 to 0C160max160max160max200max400maxIo=0 to 30%500max500max500max500max500max0 to +40C150max150max150max200max200max-10 to 0C180max180max180max240max500maxIo=0 to 30%600max600max600max600max600max0 to +40C 120max 150max 240max 360max 480maxTEMPERATURE REGULATION[mV]-10 to +40C 180max 180max 290max 440max 600maxDRIFT[mV]*248max60max96max144max192maxSTART-UP TIME[ms]500typ (ACIN 115V, Io=100%) Ta=25CHOLD-UP TIME[ms]20typ (ACIN 115V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]10.80 to 13.2013.50 to 16.5021.60 to 26.4032.40 to 39.6043.20 to 52.80OUTPUT VOLTAGE SETTING[V]12.00 to 12.4815.00 to 15.6024.00 to 24.9636.00 to 37.4448.00 to 49.92OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyOVERVOLTAGE PROTECTION[V]13.80 to 16.8017.25 to 21.0027.60 to 33.6041.40 to 50.4054.00 to 67.20OPERATING INDICATIONLED (Green)REMOTE SENSINGNot providedREMOTE ON/OFFOptional (Required external power source. Option -R)INPUT-OUTPUT RC*8AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)INPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)OUTPUT RC-FG*8AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)OUTPUT-RC*8AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *4-20 to +70C (Refer to“Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) maxVIBRATION10 - 55Hz, 19.6m/s 2 (2G), 3minutes period, 60minutes each along X, Y and Z axesIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axesAGENCY APPROVALSUL62368-1, C-UL (CSA62368-1), EN62368-1, UL508 (Except option -J, -J1) Complies with DEN-ANCONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR *7Complies with IEC61000-3-2 class APJA-2? 86 ?