title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
88/916

This page is the summary of page 88 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

PJARAC-DC Power Supplies Enclosed TypePJA100FOrdering informationPJ A 100 F -O -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-04-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6C : with CoatingR : Remote on/off(Required externalpower source)J : EP (Tyco Electronics)connector typeJ1 : VH (J.S.T.)connector typeT : Vertical terminal blockN2 : with DIN railSee 6.1 in Instruction Manual.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.SPECIFICATIONSINPUTOUTPUTPROTECTIONCIRCUIT ANDOTHERSISOLATIONENVIRONMENTSAFETY ANDNOISEREGULATIONS* Please consider "PBA100F-5-N" about 5V output with case cover.MODELPJA100F-12PJA100F-15PJA100F-24PJA100F-36PJA100F-48VOLTAGE[V]AC85 - 264 1f (Output derating is required at AC85V - 115V. Refer to“Derating”and instruction manual 1.1, 3)ACIN 100V1.2typ (Io=90%)CURRENT[A]ACIN 115V1.1typ (Io=100%)ACIN 230V0.6typ (Io=100%)FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 100V82typ (Io=90%)83typ (Io=90%)85typ (Io=90%)86typ (Io=90%)86typ (Io=90%)EFFICIENCY[%]ACIN 115V82typ (Io=100%)83typ (Io=100%)85typ (Io=100%)86typ (Io=100%)86typ (Io=100%)ACIN 230V85typ (Io=100%)86typ (Io=100%)88typ (Io=100%)89typ (Io=100%)89typ (Io=100%)ACIN 100V0.98typ (Io=90%)POWER FACTORACIN 115V0.98typ (Io=100%)ACIN 230V0.90typ (Io=100%) * Power factor correction is stopped at AC250V or more.ACIN 100V16typ (Io=90%) Ta=25C at cold startINRUSH CURRENT[A]ACIN 115V16typ (Io=100%) Ta=25C at cold startACIN 230V32typ (Io=100%) Ta=25C at cold startLEAKAGE CURRENT[mA]0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]1215243648CURRENT[A]ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to“Derating”)ACIN 115V-264V 8.4 6.7 4.3 2.8 2.1WATTAGE[W]ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to“Derating”)ACIN 115V-264V 100.8 100.5 103.2 100.8 100.8LINE REGULATION[mV]*348max60max96max144max192maxLOAD REGULATION[mV] *3RIPPLE[mVp-p]*1Io: load factorRIPPLE NOISE[mVp-p]*1Io: load factorIo=30 to 100% 100max 120max 150max 150max 300maxIo=0 to 30% Burst operation (Please contact us about detail)0 to +40C120max120max120max150max150max-10 to 0C160max160max160max200max400maxIo=0 to 30%500max500max500max500max500max0 to +40C150max150max150max200max200max-10 to 0C180max180max180max240max500maxIo=0 to 30%600max600max600max600max600max0 to +40C 120max 150max 240max 360max 480maxTEMPERATURE REGULATION[mV]-10 to +40C 180max 180max 290max 440max 600maxDRIFT[mV]*248max60max96max144max192maxSTART-UP TIME[ms]500typ (ACIN 115V, Io=100%) Ta=25CHOLD-UP TIME[ms]20typ (ACIN 115V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]10.80 to 13.2013.50 to 16.5021.60 to 26.4032.40 to 39.6043.20 to 52.80OUTPUT VOLTAGE SETTING[V]12.00 to 12.4815.00 to 15.6024.00 to 24.9636.00 to 37.4448.00 to 49.92OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyOVERVOLTAGE PROTECTION[V]13.80 to 16.8017.25 to 21.0027.60 to 33.6041.40 to 50.4054.00 to 67.20OPERATING INDICATIONLED (Green)REMOTE SENSINGNot providedREMOTE ON/OFFOptional (Required external power source. Option -R)INPUT-OUTPUT RC*8AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)INPUT-FGAC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)OUTPUT RC-FG*8AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)OUTPUT-RC*8AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *4-20 to +70C (Refer to“Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) maxSTORAGE TEMP.,HUMID.AND ALTITUDE-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) maxVIBRATION10 - 55Hz, 19.6m/s 2 (2G), 3minutes period, 60minutes each along X, Y and Z axesIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axesAGENCY APPROVALSUL62368-1, C-UL (CSA62368-1), EN62368-1, UL508 (Except option -J, -J1) Complies with DEN-ANCONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-BHARMONIC ATTENUATOR *7Complies with IEC61000-3-2 class APJA-2? 86 ?