title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
894/916

This page is the summary of page 894 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

Three phase input type (Multistage filter)TSD series(400,600A)ROrdering informationTSD -600 -1861 2 31 Series Name2 Rated Current3 Line to ground capacitor code:See table 1.1table1.1 Line to ground capacitor codeLeakage Current *1Line to ground capacitorCode Upper row : D-connection (nominal value)Lower row : Y-connectionCY1CY2CY310545mA/70mA max3.5mA/7mA max0.22μF0.1μF 0.22μF21580mA/130mA max7.5mA/15mA max1.0μF0.1μF1.0μF665220mA/350mA max20mA/40mA max2.2μF2.2μF2.2μF136420mA/660mA max40mA/80mA max2.2μF2.2μF2.2μF186540mA/850mA max50mA/100mA max2.2μF2.2μF2.2μF* When the line to ground capacitor code is different,the attenuation characteristic is different.* Please contact us about low leakage current type.(Change to low grounding capacitor)*1 D-connection : Input 250/400V 60HzY-connection : Input 250/500V 60HzFeatures of TSD seriesUltra high-attenuation type for motor drive system (Multi-functional regenerative converter)- Improve saturation resistance - Input and output terminals : Busbar type- Target application: Large equipment with Multi-functional regenerative convertor (Transferred equipment, Air conditioning equipment)SpecificationsNo.ItemsTSD-400-186TSD-600-1861Rated Voltage[V]AC Three Phase Y-connection 500 (voltage range:528 max) 50/60Hz *22Rated Current[A]4006003Test Voltage (Terminal-Mounting Plate)3,600 VDC (Cutoff Current = 10mA), 1minute at room temperature and humidity4Leakage current 250/500V 60Hz50mA/100mA max (Y-connection)5DC resistance0.27mW max0.2mW max6Safety agency approval temperatures-40 to +85C (Refer to Derating Curve)7Operating temperature-40 to +85C (Refer to Derating Curve)8Operating humidity20 to 95%RH (Non condensing)9Storage temperature/humidity-40 to +85C/20 to 95%RH (Non condensing)10Vibration10 to 55Hz, 9.8m/s 2 (1G), 3min. Period, 1hour each X, Y and Z axis11Impact98.1m/s 2 (10G), 11ms Once each X, Y and Z axis12Safety agency approvalsUL60939 [Overvoltage Category :ⅢAltitude 3000m] , CSA C22.2 No.8 (C-UL)EN60939 (DEMKO) [Overvoltage Category:ⅢAltitude 3000m] , ENEC13Case size (without projection)210×125×360 mm [8.27X4.92X14.17 inches] (WXHXD)14Weight10.0kg max10.5kg max*2 Three Phase D-connection:400V (440V max)Circuit Diagram(1) Line to ground capacitor code : 105(2) Line to ground capacitor code : 215,665Derating CurveLINECaseLOADLINECaseLOAD141410023CY1CY1CY2CY2CY3CY35623CY1CY1CY2CY2CY3CY356Load Factor [%]8070604020100-40 -30-20 40 50 6070 80 85 90CY1, CY2, CY3 : Line to ground capacitorCY1, CY2, CY3 : Line to ground capacitorAmbient Temperature [C]: Mounting Plate(3) Line to ground capacitor code : 136: Mounting Plate(4) Line to ground capacitor code : 186LINECaseLOADLINECaseLOAD141425253636CY1CY2CY3CY1CY2CY3CY1CY2CY3CY1CY2CY3EMI/EMCFilterCY1, CY2, CY3 : Line to ground capacitorCY1, CY2, CY3 : Line to ground capacitor: Mounting Plate: Mounting PlateTS-3 ? 892 ?