title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
902/916

This page is the summary of page 902 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

Single-phase and Three-phase Input TypeInstruction Manual1 Method of connectingEMI/EMC Filter2 Caution when connectingEMI/EMC Filter(1) Single-phaseLNFGLN12EMI/EMCFilter34142EMI/EMCFilter536DeviceDevicePlease note the excessive temperature increase of EMI/EMC fi lter.Please contact us if judgement is diffi cult.(1) Input voltage and frequencyPlease use within the rated voltage (or maximum voltage) of eachmodel.Input frequency specification for AC input EMI/EMC filter isconsidered as commercial frequency (50/60Hz).It should not be used under the following conditions.1) Distorted input voltage waveform.(Triangle wave, square wave etc.)2) High input frequency (ex: 400Hz)FG(2) Input currentPlease use within the rated current of each model.¶Three-phase three-wire EMI/EMC filter is also available as aSingle-phase input type.(2) Three-phase three-wireL1L2L3FG142EMI/EMCFilter536DeviceEMI/EMC fi lters have short term peak current capability. Therefore,it can fl ow ~40A or ten times of rated current, non-repeated, within afew ms such as inrush current of power supply etc.However, it should not be used under the following conditions.1) Long duration peak current.2) Peak current or high-frequency current is continuously flowing.(3) Connection to a general-purpose inverter (servo driver)Please connect EMI/EMC filter to input side of inverter driver(servo driver).It should not be used between the inverter (servo driver) and themotor.(3) Three-phase four-wireL114L22EMI/EMC5L33Filter6NNN'FGDeviceEMI/EMCFilterpossibleEMI/EMCFilterpossibleInverterorservo driverInverterorservo driverEMI/EMCFilterSingle-phaseinput typeimpossibleEMI/EMCFilterThree-phaseinput typeimpossibleMotorMotorEMI/EMCFilter[Reference] Example of calculating input current calculationInput voltage 400 [V]Input capacity of the equipment 4000 [VA]4000 [VA]Input current == 5.8 [A]400 [V]X 3(4) Caution when a Three-phase four-wire systemWhen using a Three-phase three-wire system input, deltaconnection cannot be used.When using the N and N' terminals of the EMI/EMC filter, theneutral line (N phase) must be connected.If you have a Three-phase four-wire system with a Single-phaseload connected between the neutral and each line, the neutralmay carry considerably more current than the line current.Manual-1 ? 900 ?