AME seriesOutput module specifications120W suitable single output240W suitable single outputITEMCODEJAKBLCMDE4ESNumber of slots used11111111111VOLTAGE [V]3.357.512152436483.357.5MINIMUM CURRENT [A]00000000000CURRENT [A]15.212128.5853.42.5323224PEAK CURRENT [A]*3-----------LINE REGULATION [mV] max202036486096120192202036LOAD REGULATION [mV] max40401001001201501802404040100RIPPLE [mVp-p] maxRIPPLE NOISE [mVp-p] maxTEMPERATURE COEFFICIENT [mV] max0 to +50C505090120150240300480505090DRIFT [mV] max*2202036486096120192202036OUTPUT VOLTAGE SETTING [V]3.30 to 3.405.00 to 5.157.50 to 7.80 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 3.30 to 3.405.00 to 5.157.50 to 7.80OUTPUT VOLTAGE ADJUSTMENT RANGE [V]2.64 to 3.964.0 to 6.06.0 to 9.09.6 to 14.412.0 to 18.019.2 to 28.828.8 to 43.238.4 to 57.63.0 to 6.03.0 to 6.04.5 to 9.0OVERCURRENT PROTECTION [A]Works over 105% min of rated current. Automatic recovery. Hiccup mode.Works over 105% min of rated current.Automatic recovery. Hiccup mode.OVERVOLTAGE PROTECTION [V]4.2 to 5.66.5 to 7.89.4 to 11.615.0 to 18.618.8 to 23.230.0 to 37.245.0 to 55.860.0 to 74.4Vo+1.0 to 1.5Vo+1.0 to 1.5Vo+1.0 to 1.7FUNCTIONRemote ON/OFF (RC), Alarm (LV), DC_OK (LED: Blue)Remote ON/OFF (RC), Alarm (LV), Remotesensing (+S/-S), Output voltage adjustment(VTRM), Constant output currentadjustment (ITRM), DC_OK (LED: Blue)240W suitable single outputITEMCODEF4FTG4GUH4HV4VV5Number of slots used11111111111VOLTAGE [V]7.5121515243636486575100MINIMUM CURRENT [A]00000000000CURRENT [A]20201610106.755332.25PEAK CURRENT [A]*3---1515107.57.5---LINE REGULATION [mV] max4848609696120192192300300300LOAD REGULATION [mV] max100100120150150180240240350350350RIPPLE [mVp-p] maxRIPPLE NOISE [mVp-p] maxTEMPERATURE COEFFICIENT [mV] max0 to +50C120120150240240300480480750750750DRIFT [mV] max*24848609696120192192300300300OUTPUT VOLTAGE SETTING [V]7.50 to 7.80 12.00 to 12.48 15.00 to 15.60 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 36.00 to 37.44 48.00 to 49.92 65.00 to 67.60 75.00 to 78.00 100.0 to 104.0OUTPUT VOLTAGE ADJUSTMENT RANGE [V]7.2 to 14.47.2 to 14.49.0 to 18.014.4 to 28.814.4 to 28.821.6 to 43.228.8 to 57.628.8 to 57.6 57.6 to 105.0 57.6 to 105.0 57.6 to 105.0OVERCURRENT PROTECTION [A]Works over 105%min of rated current or 101%min of peak current. Automatic recovery. Hiccup mode.OVERVOLTAGE PROTECTION [V]Vo+1.2 to 2.4Vo+1.2 to 2.4Vo+1.5 to 3.0Vo+2.4 to 4.8Vo+2.4 to 4.8Vo+3.6 to 7.2Vo+4.8 to 7.2Vo+4.8 to 7.2 Vo+7.5 to 11.3 Vo+7.5 to 11.3 Vo+7.5 to 11.3FUNCTIONRemote ON/OFF (RC), Alarm (LV), Remote sensing (+S/-S), Output voltage adjustment (VTRM),Constant output current adjustment (ITRM), DC_OK (LED: Blue)300W suitable single output150W isolated dual outputITEMCODE2C2M2DP*4Q*4RNumber of slots used222111VOLTAGE [V]243648V1:12V2:12V1:15V2:15V1:24V2:24MINIMUM CURRENT [A]000000000CURRENT [A]149.37887733PEAK CURRENT [A]*315107.5101088--LINE REGULATION [mV] max96120192484860609696LOAD REGULATION [mV] max150180240100100120120150150RIPPLE [mVp-p] maxRIPPLE NOISE [mVp-p] maxTEMPERATURE COEFFICIENT [mV] max0 to +50C240300480120120150150350350DRIFT [mV] max*296120192484860609696OUTPUT VOLTAGE SETTING [V]24.00 to 24.9636.00 to 37.4448.00 to 49.9212.00 to 12.4812.00 to 12.4815.00 to 15.6015.00 to 15.6023.88 to 24.9623.88 to 24.96OUTPUT VOLTAGE ADJUSTMENT RANGE [V]14.4 to 28.821.6 to 43.228.8 to 57.65.0 to 13.25.0 to 13.25.0 to 16.55.0 to 16.55.0 to 25.25.0 to 25.2OVERCURRENT PROTECTION [A]OVERVOLTAGE PROTECTION [V]Vo+2.4 to 4.8Vo+3.6 to 7.2Vo+4.8 to 7.215.0 to 18.615.0 to 18.618.8 to 23.218.8 to 23.230.0 to 37.230.0 to 37.2Remote ON/OFF (RC), Alarm (LV), RemoteFUNCTIONsensing (+S/-S), Output voltage adjustmentRemote ON/OFF (RC) Alarm (LV) DC_OK (LED: Blue)(VTRM), Constant output currentadjustment (ITRM), DC_OK (LED: Blue)*1 Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKUGIKEN: RM104).*2 Drift is the change in DC output for an eight hours period after a half-hour warm-up at 25C.*3 The peak current should be under the following conditions.Duration: 5s or lessDuty: 35% or lessAverage current: Rated current or less*4 The total output power of V1 and V2 must be less than output power (P: 153.6W, Q: 165W).AME-3