title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
905/1330

This page is the summary of page 905 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AME seriesOutput module specifications120W suitable single output240W suitable single outputITEMCODEJAKBLCMDE4ESNumber of slots used11111111111VOLTAGE [V]3.357.512152436483.357.5MINIMUM CURRENT [A]00000000000CURRENT [A]15.212128.5853.42.5323224PEAK CURRENT [A]*3-----------LINE REGULATION [mV] max202036486096120192202036LOAD REGULATION [mV] max40401001001201501802404040100RIPPLE [mVp-p] maxRIPPLE NOISE [mVp-p] maxTEMPERATURE COEFFICIENT [mV] max0 to +50C505090120150240300480505090DRIFT [mV] max*2202036486096120192202036OUTPUT VOLTAGE SETTING [V]3.30 to 3.405.00 to 5.157.50 to 7.80 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 3.30 to 3.405.00 to 5.157.50 to 7.80OUTPUT VOLTAGE ADJUSTMENT RANGE [V]2.64 to 3.964.0 to 6.06.0 to 9.09.6 to 14.412.0 to 18.019.2 to 28.828.8 to 43.238.4 to 57.63.0 to 6.03.0 to 6.04.5 to 9.0OVERCURRENT PROTECTION [A]Works over 105% min of rated current. Automatic recovery. Hiccup mode.Works over 105% min of rated current.Automatic recovery. Hiccup mode.OVERVOLTAGE PROTECTION [V]4.2 to 5.66.5 to 7.89.4 to 11.615.0 to 18.618.8 to 23.230.0 to 37.245.0 to 55.860.0 to 74.4Vo+1.0 to 1.5Vo+1.0 to 1.5Vo+1.0 to 1.7FUNCTIONRemote ON/OFF (RC), Alarm (LV), DC_OK (LED: Blue)Remote ON/OFF (RC), Alarm (LV), Remotesensing (+S/-S), Output voltage adjustment(VTRM), Constant output currentadjustment (ITRM), DC_OK (LED: Blue)240W suitable single outputITEMCODEF4FTG4GUH4HV4VV5Number of slots used11111111111VOLTAGE [V]7.5121515243636486575100MINIMUM CURRENT [A]00000000000CURRENT [A]20201610106.755332.25PEAK CURRENT [A]*3---1515107.57.5---LINE REGULATION [mV] max4848609696120192192300300300LOAD REGULATION [mV] max100100120150150180240240350350350RIPPLE [mVp-p] maxRIPPLE NOISE [mVp-p] maxTEMPERATURE COEFFICIENT [mV] max0 to +50C120120150240240300480480750750750DRIFT [mV] max*24848609696120192192300300300OUTPUT VOLTAGE SETTING [V]7.50 to 7.80 12.00 to 12.48 15.00 to 15.60 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 36.00 to 37.44 48.00 to 49.92 65.00 to 67.60 75.00 to 78.00 100.0 to 104.0OUTPUT VOLTAGE ADJUSTMENT RANGE [V]7.2 to 14.47.2 to 14.49.0 to 18.014.4 to 28.814.4 to 28.821.6 to 43.228.8 to 57.628.8 to 57.6 57.6 to 105.0 57.6 to 105.0 57.6 to 105.0OVERCURRENT PROTECTION [A]Works over 105%min of rated current or 101%min of peak current. Automatic recovery. Hiccup mode.OVERVOLTAGE PROTECTION [V]Vo+1.2 to 2.4Vo+1.2 to 2.4Vo+1.5 to 3.0Vo+2.4 to 4.8Vo+2.4 to 4.8Vo+3.6 to 7.2Vo+4.8 to 7.2Vo+4.8 to 7.2 Vo+7.5 to 11.3 Vo+7.5 to 11.3 Vo+7.5 to 11.3FUNCTIONRemote ON/OFF (RC), Alarm (LV), Remote sensing (+S/-S), Output voltage adjustment (VTRM),Constant output current adjustment (ITRM), DC_OK (LED: Blue)300W suitable single output150W isolated dual outputITEMCODE2C2M2DP*4Q*4RNumber of slots used222111VOLTAGE [V]243648V1:12V2:12V1:15V2:15V1:24V2:24MINIMUM CURRENT [A]000000000CURRENT [A]149.37887733PEAK CURRENT [A]*315107.5101088--LINE REGULATION [mV] max96120192484860609696LOAD REGULATION [mV] max150180240100100120120150150RIPPLE [mVp-p] maxRIPPLE NOISE [mVp-p] maxTEMPERATURE COEFFICIENT [mV] max0 to +50C240300480120120150150350350DRIFT [mV] max*296120192484860609696OUTPUT VOLTAGE SETTING [V]24.00 to 24.9636.00 to 37.4448.00 to 49.9212.00 to 12.4812.00 to 12.4815.00 to 15.6015.00 to 15.6023.88 to 24.9623.88 to 24.96OUTPUT VOLTAGE ADJUSTMENT RANGE [V]14.4 to 28.821.6 to 43.228.8 to 57.65.0 to 13.25.0 to 13.25.0 to 16.55.0 to 16.55.0 to 25.25.0 to 25.2OVERCURRENT PROTECTION [A]OVERVOLTAGE PROTECTION [V]Vo+2.4 to 4.8Vo+3.6 to 7.2Vo+4.8 to 7.215.0 to 18.615.0 to 18.618.8 to 23.218.8 to 23.230.0 to 37.230.0 to 37.2Remote ON/OFF (RC), Alarm (LV), RemoteFUNCTIONsensing (+S/-S), Output voltage adjustmentRemote ON/OFF (RC) Alarm (LV) DC_OK (LED: Blue)(VTRM), Constant output currentadjustment (ITRM), DC_OK (LED: Blue)*1 Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKUGIKEN: RM104).*2 Drift is the change in DC output for an eight hours period after a half-hour warm-up at 25C.*3 The peak current should be under the following conditions.Duration: 5s or lessDuty: 35% or lessAverage current: Rated current or less*4 The total output power of V1 and V2 must be less than output power (P: 153.6W, Q: 165W).AME-3