title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
916/1330

This page is the summary of page 916 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Confi gurable TypeInstruction Manual1 Configuration - ModelName Construction!Order Name Construction1 to 3 are same rules as Model Name. After that, add managementnumber (6 digits).Parallel and series code are not listed on Order name.The AME series has Order Name which is used for the orderingaside from Model Name.AM12 - O D C C B A - O O O O O OO : management number (6digits)O : Alphanumeral!Model Name ConstructionOutput modules654321Code CodeAM12345Bar for SeriesBar for ParallelCode6?Note(1) Please select the output module codes from the specifi cationsto correspond with required voltage and current.Please select”O”when the slot is blank.(2) If the output modules need to be connected in parallel or series,please select Parallel or Series code from Table1.1.(3) At least two slots have to be occupied.(4) The following is the list of modules which can be used in seriesor parallel operation.654 3slot1ModelAM=AME series2Power04=400W, 06=600W, 08=800W, 12=1200W3Output module confi gurationThe output module codes are showed in the specifi cations.When the slot is blank,“O”(Alphabet) needs to be set.¶The number of slot is different depending on the model.4Parallel codeRefer to Table2.1 Parallel and Series Code.5Series codeRefer to Table2.1 Parallel and Series Code.6Option codeRefer to section 7.?Model Name example (1)AM12 ODCCBA 0004 C21Example of optionParallel connection is not necessary.Slot1 Module A 5V 12ASlot2 Module B 12V 8.5ASlot3, 4Two Module C in seriesat 48V 5ASlot5 Module D 48V 2.5ASlot6 is blankAME1200F?Model Name example (2)If the series operating module C (48V,5A) in example (1) ischanged to module 2D[48V, 7(7.5)A)], the part number wouldchange to AM12-OO2DBA-0000-C.?Model Name example (3)Parallel and series operation of 2C-2M both use codes as in Table 1.1.For example, if connecting two modules 2C [24V, 14(15)A] inseries, and using these as 48V, 14(15)A, the part number wouldchange to AM12-OO2C2C-0006.AME-14Series settingParallel settingAME400F/AME600FAME800F/AME1200FCode000102030405060708090A0B0C0D0E0F101112131415161718191A1B1C1D1E1FAvailable output modulesA-C, J-L, E4-G4, E-G, S, T, 2CE4-H4, E-H, S-V, V4, V5, 2C-2MTable 1.1 Parallel and Series Code.Slot6 Slot5 Slot4 Slot3 Slot2 Slot1: Output terminal: Connection