Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
PJARAC-DC Power Supplies Enclosed TypePJA300FOrdering informationPJ A 300 F -O -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-06-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series* A higher current rating EMI/EMC filtermay be recommended in view of theother devices that could be connectedin parallel with the power supply.1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *6C : with CoatingG : Low leakage currentV : External potentiometer foroutput voltage adjustmentR : Remote on/off(Required external power source)F4: Low speed fanSee 6.1 in Instruction Manual.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.SPECIFICATIONSMODELPJA300F-5PJA300F-12PJA300F-15PJA300F-24PJA300F-36PJA300F-48VOLTAGE[V]AC85 - 264 1f (Output derating is required at AC85V - 100V. Refer to“Derating”and instruction manual 1.1, 3)ACIN 100V3.5typ (Io=100%)3.9typ (Io=100%)CURRENT[A]ACIN 115V3.0typ (Io=100%)3.3typ (Io=100%)ACIN 230V1.5typ (Io=100%)1.7typ (Io=100%)FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 100V73typ (Io=100%)79typ (Io=100%)81typ (Io=100%)82typ (Io=100%)83typ (Io=100%)82typ (Io=100%)EFFICIENCY[%]ACIN 115V74typ (Io=100%)80typ (Io=100%)82typ (Io=100%)83typ (Io=100%)83typ (Io=100%)83typ (Io=100%)INPUTACIN 230V77typ (Io=100%)82typ (Io=100%)84typ (Io=100%)86typ (Io=100%)87typ (Io=100%)86typ (Io=100%)ACIN 100V0.99typ (Io=100%)POWER FACTORACIN 115V0.98typ (Io=100%)ACIN 230V0.95typ (Io=100%)ACIN 100V20typ (Io=100%) Ta=25C at cold startINRUSH CURRENT[A]ACIN 115V20typ (Io=100%) Ta=25C at cold startACIN 230V40typ (Io=100%) Ta=25C at cold startLEAKAGE CURRENT[mA]0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]51215243648CURRENT[A]ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to“Derating”)ACIN 100V-264V 50 25 20 12.5 8.4 6.3WATTAGE[W]ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to“Derating”)ACIN 100V-264V 250 300 300 300 302.4 302.4LINE REGULATION[mV]*320max48max60max96max144max192maxLOAD REGULATION[mV]*340max100max120max150max150max300maxRIPPLE[mVp-p]0 to +50C80max120max120max120max150max150maxOUTPUT*1 -10 to 0C 140max 160max 160max 160max 160max 400maxRIPPLE NOISE[mVp-p] 0 to +50C 120max 150max 150max 150max 200max 200max*1-10 to 0C160max180max180max180max240max500max0 to +50C 50max 120max 150max 240max 360max 480maxTEMPERATURE REGULATION[mV]-10 to +50C 75max 180max 180max 290max 440max 600maxDRIFT[mV]*220max48max60max96max144max192maxSTART-UP TIME[ms]300typ (ACIN 100V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 100V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]4.50 to 5.5010.80 to 13.2013.50 to 16.5021.60 to 26.4032.40 to 39.6043.20 to 52.80OUTPUT VOLTAGE SETTING[V]5.00 to 5.1512.00 to 12.4815.00 to 15.6024.00 to 24.9636.00 to 37.4448.00 to 49.92OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyPROTECTIONOVERVOLTAGE PROTECTION[V]5.75 to 7.0013.80 to 16.8017.25 to 21.0027.60 to 33.6041.40 to 50.4055.20 to 67.20CIRCUIT ANDOPERATING INDICATIONLED (Green)OTHERSREMOTE SENSINGNot providedREMOTE ON/OFFOptional (Required external power source. Option -R)INPUT-OUTPUT RC*9AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)ISOLATIONOUTPUT-RC*9AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *4-20 to +70C (Refer to“Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axesSAFETY ANDAGENCY APPROVALSUL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-BREGULATIONSHARMONIC ATTENUATOR *8Complies with IEC61000-3-2 class APJA-6? 90 ?