title: COSEL Power Supply, Noise Filter 2025 Product Catalog

page
923/1330

This page is the summary of page 923 of the ebook "COSEL Power Supply, Noise Filter 2025 Product Catalog."

You can click "Open This Page" or "Open 1st Page" button, and open the ebook.

Summary

COSEL Power Supply, Noise Filter 2025 Product Catalog

AC-DC Power Supplies Confi gurable TypeInstruction Manual- All output modules have the reversed logic of the remote ON, ifthe -R is specifi ed.- The harness for CN3 is required when using this option.- Please contact us if the mix of the standard and the reversedlogic is required.?-J2- Every module in the unit of -J2 option have Molex connectorsinstead of a terminal block.- Please contact us for details about appearance.- The maximum current per pin is 8A.CN3CN3414 8+V+V-V-V1 5CN5CN5?-J3- The unit of -J3 option has the following connectors for functions.Table 6.4 Connectors and Terminals for -J3 optionConnectorMating ConnectorTerminalMfr.CN1CN387833-103151110-105650394-8051MolexCN287833-083151110-085650394-8051Molex?-C- Except a certain (e.g.terminal, potentionmeter), PCB is coated.?-F3-The cooling fan direction is reversed from the standard model.- Fig. 6.2 is the direction of air fl ow and Fig. 6.3 is the temperaturederating.-Please contact us for the life expectancy of fan.Module:A-D,K-MCN3Module:E4-H4,E-H,S-V,V4,V5,2C-2M*AWG16 should be used for CN5Air flowFANOutputmodule4 81 5+V1-V1+V2-V2CN5Module:P,Q,RFig.6.1 Example of -J2 optionTable 6.1 Connectors and Terminals for -J2 option(Applying module : A-D, K-M)ConnectorMating ConnectorTerminalMfr.CN5393030463901404145750-3111MolexTable 6.2 Connectors and Terminals for -J2 option(Applying module : E4-H4, E-H, J, S-V, V4, V5, 2C-2M, P, Q, R)ConnectorMating ConnectorTerminalMfr.CN5393000803901208545750-3111MolexTable 6.3 Function of specifi cation pinsAppling modulePin numbersE4-H4 ,E-H, J,A-D,K-MS-V, V4, V5, 2C-2MP, Q, R1-V-V-V22-V-V+V23+V+V-V14+V+V+V15--V-V26--V+V27-+V-V18-+V+V1?-GLoad of output module [%]10080604020Fig. 6.2 Air fl ow(-F3 option)0-20 -10 0 10 20 25 30 40 50 60 70Ambient temperature [a]Fig.6.3 Derating curve for ambient temperature (-F3 option)!The spec of leakage current is lower than the standard model.!Differences from standard model are summarized in Table 6.5.?-I3Table 6.5 Low leakage current typeLeakage Current(240VAC)Conducted NoiseOutput Ripple Noise0.15mA maxN/A150% of standard units!The power supply provides an“Extended-UART”digital interface.!Extended-UART is the communication protocol that enable singlewireand bidirectional communications among multiple machinesby using the software with being isolated from UART which is thegeneral purpose communication.Please refer to“AME Series Extended-UART Manual”for details.AME-21