Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
AC-DC Power Supplies DIN Rail TypeInstruction Manual4 TemperatureMeasurement Point? KHEA90F, KHNA90FTB2POINT B *(C515)!Ambient temperature indicates the temperature of the inlet of theair.TB1POINT A(C106)** Please be careful of electric shock or earth leakage in case of temperature measurement,because POINT A and POINT B is live potential.Fig.4.4 Temperature measurement point (Forced air)AirflowAmbient temperaturemeasurement pointFig.4.1 Ambient temperature measurement point!Temperature of Forced airPlease use at the temperature dose not exceed the values inTable 4.1. If you need to measure temperature, please contact us.Please also make sure that the ambient temperature does not exceed70C.? KHEA30F, KHNA30FPOINT C(T201)Table 4.1 Specifi ed temperature of the measurement pointNo.ModelTemperature measurement pointPoint A Point B Point C1KHEA30F, KHNA30F80C80C105C2KHEA60F, KHNA60F80C80C105C3KHEA90F, KHNA90F80C80C? KHEA120F/240F/480F, KHNA120F/240F/480FUse the temperature measurement point as shown in Fig 4.5.Please use at the temperature does not exceed the values inTable 4.2.Please also make sure that the ambient temperature does not exceed70C.TB2POINT B(C515)Temperaturemeasureing pointAirflowPOINT A(C106)TB1Fig.4.2 Temperature measurement point (Forced air)? KHEA60F, KHNA60FTB2POINT B(C516)POINT C(T201)AirflowFig.4.5 Temperature measurement point (Forced air)Table 4.2 Specifi ed temperature of the measurement pointNo.Modeltemperature measurement point1KHEA120F, KHNA120F75C2KHEA240F, KHNA240F80C3KHEA480F, KHNA480F85CTB1POINT A(C107)Fig.4.3 Temperature measurement point (Forced air)KH-25