Summary
COSEL Power Supply, Noise Filter 2025 Product Catalog
PJARAC-DC Power Supplies Enclosed TypePJA1500FOrdering informationPJ A 1500 F -O -O1 2 3 4 5 6Example recommended EMI/EMC filterNAC-20-472High voltage pulse noise type : NAP seriesLow leakage current type : NAM series1 Series name2 Single output3 Output wattage4 Universal input5 Output voltage6 Optional *8C : with CoatingG : Low leakage currentV : External potentiometer foroutput voltage adjustmentW : Parallel operation, LV alarmand Remote sensingR : Remote on/off(Required external powersource)See 6.1 in Instruction Manual.*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.SPECIFICATIONSMODELPJA1500F-12PJA1500F-15PJA1500F-24PJA1500F-36PJA1500F-48VOLTAGE[V]AC85 - 264 1f (Output derating is required at AC85V - 115V. Refer to“Derating”and instruction manual 1.1, 3)ACIN 100V18typ (Io=90%)CURRENT[A]ACIN 115V16typ (Io=100%)ACIN 230V8typ (Io=100%)FREQUENCY[Hz]50 / 60 (47 - 63)ACIN 100V81typ (Io=90%)82typ (Io=90%)84typ (Io=90%)84typ (Io=90%)84typ (Io=90%)EFFICIENCY[%]ACIN 115V82typ (Io=100%)82typ (Io=100%)85typ (Io=100%)85typ (Io=100%)84typ (Io=100%)INPUTACIN 230V85typ (Io=100%)85typ (Io=100%)88typ (Io=100%)88typ (Io=100%)87typ (Io=100%)ACIN 100V0.98typ (Io=90%)POWER FACTORACIN 115V0.98typ (Io=100%)ACIN 230V0.95typ (Io=100%)ACIN 100V15/30typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)INRUSH CURRENT[A]ACIN 115V15/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)ACIN 230V30/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)LEAKAGE CURRENT[mA]1.5max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)VOLTAGE[V]1215243648CURRENT[A]ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to“Derating”)ACIN 115V-264V 125 100 64 42 32WATTAGE[W]ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to“Derating”)ACIN 115V-264V 1500 1500 1536 1512 1536LINE REGULATION[mV]*248max60max96max144max192maxLOAD REGULATION[mV]*2100max120max150max150max300maxRIPPLE[mVp-p]0 to +50C180max180max120max150max200maxOUTPUT*1 -20 to 0C 240max 240max 160max 200max 500maxRIPPLE NOISE[mVp-p] 0 to +50C 210max 210max 150max 200max 300max*1-20 to 0C270max270max270max240max600max0 to +50C 120max 150max 240max 360max 480maxTEMPERATURE REGULATION[mV]-20 to +50C 180max 180max 290max 440max 600maxDRIFT[mV]*348max60max96max144max192maxSTART-UP TIME[ms]800typ (ACIN 115V, Io=100%)HOLD-UP TIME[ms]20typ (ACIN 115V, Io=100%)OUTPUT VOLTAGE ADJUSTMENT RANGE[V]10.80 to 13.5013.50 to 17.3020.40 to 28.5030.60 to 40.8040.80 to 55.20OUTPUT VOLTAGE SETTING[V]12.00 to 12.4815.00 to 15.6024.00 to 24.9636.00 to 37.4448.00 to 49.92OVERCURRENT PROTECTIONWorks over 105% of rating and recovers automaticallyPROTECTIONOVERVOLTAGE PROTECTION[V]14.40 to 17.4018.00 to 21.8028.80 to 34.8043.20 to 52.2057.00 to 67.20CIRCUIT ANDOPERATING INDICATIONLED (Green)OTHERSREMOTE SENSINGOptional (Option -W)REMOTE ON/OFFOptional (Required external power source. Option -R)INPUT-OUTPUTAC3,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature)ISOLATIONINPUT-FGAC2,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature)OUTPUT-FGAC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)OPERATING TEMP.,HUMID.AND ALTITUDE *4-20 to +70C (Refer to“Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) maxENVIRONMENTIMPACT196.1m/s 2 (20G), 11ms, once each X, Y and Z axesSAFETY ANDAGENCY APPROVALSUL62368-1, C-UL (CSA62368-1), EN62368-1, Complies with DEN-ANNOISECONDUCTED NOISEComplies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A, additional EMI/EMC Filter is required for meeting class BREGULATIONSHARMONIC ATTENUATOR *5Complies with IEC61000-3-2 class APJA-12? 96 ?