Purchase Products Contact Us

Products

BRFS50L

  • Production discontinued (November 20, 2019)
  • UL60950-1
  • C-UL (CSA60950-1)
  • EN62368-1
  • RoHS
    UL・C-UL
    TUV
    CE
    UKCA
Rated Input: DC4.5 - 14.0V
Rated Output Current: 50A

• Small size and high efficiency non-isolated DC-DC converter
• Wide input voltage 4.5V to 14.0V
• Fast transient response by robust control
• Built-in remote ON/OFF, Power good, Start-up sequence

Free warranty period 5-year

Technical features

  • Adjustable Output Voltage
  • Remote Control
  • Remote sensing
  • Parallel Operation
  • Alarm
Type Model number Description PDF DXF
Instruction manual
Applications manual
How to remove BRNS/BRFS series from a PWB

*Some documents may not be listed. Please contact us for more details.

CAD data download

CAD data DXF Standard model
3D CAD data STEP Standard model
IGES Standard model

Block diagram

BRF(1)  S(2)  50(3)  L(4)  -  (5)


(1) Series name
(2) Single output
(3) Output current
   30: 30A
   40: 40A
   50: 50A
   60: 60A
  100: 100A
  120: 120A
  150: 150A
(4) Type
   Blank: Standard type
   L: Low profile type (only 50A)
   S: Small type (only 60A)
(5) Optional
   R: Positive logic remote on/off
   I: POWERGOOD (only BRFS30/40/60S)
     *Other models has POWERGOOD function normally.
   P: Parallel operation (only BRFS40/60S)
   Y1: Fast transient response (only BRFS100)

BRFS50L specifications (overview)

Product BRFS50L
Input voltage DC4.5 - 14.0V
Output Wattage
Voltage・Current 1.2V 50.0A
Voltage variable range Adjustable by external resistor0.7 - 2.0V
Applicable standards Safety Certifications UL60950-1, C-UL (CSA60950-1) , EN62368-1
Structure External dimensions (W×H×D) 33.0x7.0x22.9mm [1.3x0.28x0.9 incges]
Cooling method Convection/Forced air
Technical data Characteristic data
Estimated life data -
EMC data
Reliability
MTBF

* For further information and how to use, please see in Cosel product catalog.