Rated Input: DC36 - 76V *
Rated Output Wattage: 450W
Rated Output Voltage: 24V,28V,32V
*Input voltage range depends on model

• Compact DC-DC Converter in the Standard “HALF BRICK” Size
• Built-in remote ON/OFF
• Mounting hole (M3 tapped)

Free warranty period 5-year

Technical features

Type Model number Description PDF DXF
Heat sink
F-CBS-F1 Heatsink for TUNS100, CBS, DHS200, DHS250 series.
(Horizontal style)
PDF download -
F-CBS-F2 Heatsink for TUNS100, CBS, DHS200, DHS250 series.
(Vertical style)
PDF download -
F-CBS-F3 Heatsink for TUNS100, CBS, DHS200, DHS250 series.
(Horizontal style)
PDF download -
F-CBS-F4 Heatsink for TUNS100, CBS, DHS200, DHS250 series.
(Vertical style)
PDF download -
F-CBS-F5 Heatsink for TUNS100, CBS, DHS200, DHS250 series.
(Horizontal style)
PDF download -
F-CBS-F6 Heatsink for TUNS100, CBS, DHS200, DHS250 series.
(Vertical style)
PDF download -
Instruction manual

*Some documents may not be listed. Please contact us for more details.

CAD data download

CAD data DXF Standard model
3D CAD data STEP Standard model
IGES Standard model

Block diagram

  • CHS400

    • UL60950-1
    • C-UL (CSA60950-1)
    • EN62368-1
    • RoHS
      PMBus

    Rated Input:DC18 - 36V,DC36 - 76V
    Rated Output Wattage:318 - 400W
    Output Voltage:10V,12V,15V,24V,28V,32V,48V

CB(1)  S(2)  450(3)  48(4)  28(5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Input voltage
  48: DC36 - 76V
(5) Output voltage
(6) Optional
  R: with Remote ON/OFF
    Positive logic control
  T: with Mounting hole φ3.4 thru
  F□: with Addition of a Heat sink

CBS450 specifications (overview)

Product CBS4504824 CBS4504828 CBS4504832
Input voltage DC38 - 60V DC36 - 76V DC36 - 76V
Output Wattage 456W 448W 400W
Voltage・Current 24V 19A 28V 16A 32V 12.5A
Voltage variable range Fixed (TRM pin open), adjustable by external resistor19.2 - 26.0V Fixed (TRM pin open), adjustable by external resistor16.8 - 32.2V Fixed (TRM pin open), adjustable by external resistor25.6 - 35.2V
Applicable standards Safety Certifications UL60950-1, C-UL, EN62368-1
Structure External dimensions (W×H×D) 57.9x12.7x61.0mm [2.28x0.5x2.4 inches]
Cooling method Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Technical data Characteristic data
Estimated life data - - -
EMC data
Reliability
MTBF

* For further information and how to use, please see in Cosel product catalog.