Rated Input: DC45 - 160V
Rated Output Wattage: 100W
Rated Output Voltage: 5V,13.8V

• Ideal for distributed power systems
• Built-in thermal protection circuits
• Built-in remote ON/OFF (On both side of input and output)
• Inverter operating monitoring (IOG)
• N+1 redundant operation

Free warranty period 5-year

Technical features

  • Adjustable Output Voltage
  • Remote Control
  • Remote sensing
  • Alarm
  • Parallel Operation
  • Auxiliary Power
Type Model number Description PDF DXF
Instruction manual
PCB reference design data

*Some documents may not be listed. Please contact us for more details.

CAD data download

Block diagram

  • DHS100A

    • Active (NRND)
    • UL60950-1
    • C-UL (CSA60950-1)
    • EN62368-1
    • RoHS
    Rated Input: DC60 - 160V
    Rated Output Wattage: 100W
    Rated Output Voltage: 5V,12V,15V,24V

DB(1)  S(2)  100(3)  A(4)  15(5)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Input voltage
  A: DC110V input
(5) Output voltage

DBS100A specifications (overview)

Product DBS100A05 DBS100A13R8
Input voltage DC45 - 160V DC45 - 160V
Output Wattage 100W 100.7W
Voltage・Current 5V 20A 13.8V 7.3A
Voltage variable range Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage
Applicable standards Safety Certifications UL60950-1, C-UL, EN62368-1
Structure External dimensions (W×H×D) 61x12.7x116.8mm [2.4x0.5x4.6 inches]
Cooling method Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Technical data Characteristic data
Estimated life data - -
EMC data
Reliability
MTBF

* For further information and how to use, please see in Cosel product catalog.