Purchase Products Contact Us

Products

DBSseries

DBS100A

  • Production discontinued (May 31, 2023)
  • UL60950-1
  • C-UL
  • EN62368-1
  • RoHS
    UL・C-UL
    TUV
    CE
    UKCA
Rated Input: DC45 - 160V
Rated Output Wattage: 100W
Rated Output Voltage: 5V,13.8V

• Ideal for distributed power systems
• Built-in thermal protection circuits
• Built-in remote ON/OFF (On both side of input and output)
• Inverter operating monitoring (IOG)
• N+1 redundant operation

Free warranty period 5-year

Release year: 2003

Technical features

  • Adjustable Output Voltage
  • Remote Control
  • Remote sensing
  • Alarm
  • Parallel Operation
  • Auxiliary Power
Type Model number Description PDF DXF
Instruction manual
PCB reference design data

*Some documents may not be listed. Please contact us for more details.

CAD data download

DB(1)  S(2)  100(3)  A(4)  15(5)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Input voltage
  A: DC110V input
(5) Output voltage

DBS100A specifications (overview)

Product DBS100A05 DBS100A13R8
Input voltage DC45 - 160V DC45 - 160V
Output Wattage 100W 100.7W
Voltage・Current 5V 20A 13.8V 7.3A
Voltage variable range Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage
Applicable standards Safety Certifications UL60950-1, C-UL, EN62368-1
Structure External dimensions (W×H×D) 61x12.7x116.8mm [2.4x0.5x4.6 inches]
Cooling method Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Technical data Characteristic data
Estimated life data - -
EMC data
Reliability
MTBF

* For further information and how to use, please see in Cosel product catalog.