Purchase Products Contact Us

Products

DBSseries

DBS400B

  • Production discontinued (November 20, 2023)
  • UL60950-1
  • C-UL
  • EN62368-1Complies with DEN-AN and IEC60950-1
  • RoHS
    UL・C-UL
    TUV
    CE
    UKCA
Rated Input: DC200 - 400V
Rated Output Wattage: 400W
Rated Output Voltage: 3.3V,5V,7.5V,12V,15V,18V,24V,28V

• Ideal for distributed power systems
• Built-in thermal protection circuits
• Built-in remote ON/OFF (On both side of input and output)
• Inverter operating monitoring (IOG)
• N+1 redundant operation

Free warranty period 5-year

Technical features

  • Adjustable Output Voltage
  • Remote Control
  • Remote sensing
  • Alarm
  • Parallel Operation
  • Auxiliary Power
Type Model number Description PDF DXF
Instruction manual
PCB reference design data

*Some documents may not be listed. Please contact us for more details.

CAD data download

CAD data DXF Standard model
3D CAD data STEP Standard model
IGES Standard model

Block diagram

DB(1)  S(2)  400(3)  B(4)  03(5)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Input voltage
    B: DC200 - 400V
(5) Output voltage

DBS400B specifications (overview)

Product DBS400B03 DBS400B05 DBS400B07 DBS400B12 DBS400B15 DBS400B18 DBS400B24 DBS400B28
Input voltage DC200 - 400V DC200 - 400V DC200 - 400V DC200 - 400V DC200 - 400V DC200 - 400V DC200 - 400V DC200 - 400V
Output Wattage 264W 400W 405W 408W 405W 396W 408W 406W
Voltage・Current 3.3V 80A 5V 80A 7.5V 54A 12V 34A 15V 27A 18V 22A 24V 17A 28V 14.5A
Voltage variable range Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage
Applicable standards Safety Certifications UL60950-1, C-UL, EN62368-1Complies with DEN-AN and IEC60950-1
Structure External dimensions (W×H×D) 61x12.7x116.8mm [2.4x0.5x4.6 inches]
Cooling method Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Technical data Characteristic data
Estimated life data - - - - - - - -
EMC data
Reliability
MTBF