Purchase Products Contact Us

Products

DHSseries

DHS100A

  • Active (NRND)
  • UL60950-1
  • C-UL (CSA60950-1)
  • EN62368-1
  • RoHS
    UL・C-UL
    TUV
    CE
    UKCA
Rated Input: DC60 - 160V
Rated Output Wattage: 100W
Rated Output Voltage: 5V,12V,15V,24V

• Compact DC-DC Converter, "BRICK SIZE" which has been standard size for Telecommunication Market
• Built-in thermal protection circuits
• Built-in remote ON/OFF
• For railway applications (DHS50A, DHS100A, and DHS200A with EN50155's requirement for vibration and impact test)

Free warranty period 5-year

Technical features

  • Adjustable Output Voltage
  • Remote Control

Heat sink

Type Model number Description PDF DXF
Heat sink
F-QB-F1 Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Horizontal style) PDF download -
F-QB-F2 Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Vertical style) PDF download -
F-QB-F3 Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Horizontal style) PDF download -
F-QB-F4 Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Vertical style) PDF download -
F-QB-F5 Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Horizontal style) PDF download -
F-QB-F6 Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Vertical style) PDF download -
Instruction manual
Optional parts (sold separately)
PCB reference design data

*Some documents may not be listed. Please contact us for more details.

CAD data download

CAD data DXF Standard model
3D CAD data STEP Standard model
IGES Standard model

Block diagram

DH(1)  S(2)  100(3)  A(4)  05(5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) A: DC60 - 160V
(5) Output voltage
(6) Optional
  T: with Mounting hole
  (φ3.4 thru)

DHS100A specifications (overview)

Product DHS100A05 DHS100A12 DHS100A15 DHS100A24
Input voltage DC60 - 160V DC60 - 160V DC60 - 160V DC60 - 160V
Output Wattage 100.0W 100.8W 100.5W 100.8W
Voltage・Current 5V 20A 12V 8.4A 15V 6.7A 24V 4.2A
Voltage variable range Fixed (TRM pin open), adjustable by external VR or external voltage4.50 - 6.00V Fixed (TRM pin open), adjustable by external VR or external voltage10.80 - 13.20V Fixed (TRM pin open), adjustable by external VR or external voltage13.50 - 16.50V Fixed (TRM pin open), adjustable by external VR or external voltage21.60 - 26.40V
Applicable standards Safety Certifications UL60950-1, C-UL (CSA60950-1) , EN62368-1
Structure External dimensions (W×H×D) 58.4x12.7x37.3mm [2.3x0.5x1.47 inches]
Cooling method Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Technical data Characteristic data
Estimated life data - - - -
EMC data
Reliability
MTBF

* For further information and how to use, please see in Cosel product catalog.